EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Quantifying the Temporal Resolution of Gas-Induced Ultrasound Changes Following Percutaneous Electrolysis in Tendon Tissue. A Cadaveric Study

Miguel Malo-Urriés, Jacobo Rodríguez-Sanz, Sergio Borrella-Andrés, Isabel Albarova-Corral, Izarbe Ríos-Asín, Carlos López-de-Celis

Invasive Physiotherapy and Musculoskeletal Medicine · 21.11.2025 · 1 (1) · e17

DOI: 10.63360/ipmm.v1.e17 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Invasive Physiotherapy and Musculoskeletal Medicine, online erschienen am 21.11.2025. Verfasst von Miguel Malo-Urriés und 5 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To quantitatively assess the temporal evolution of the electrolytic ultrasonographic effect induced by percutaneous electrolysis on cadaveric patellar tendons, and to compare the behavior of three different application protocols.

Methods

An in vitro experimental study was performed on three cadaveric patellar tendons. Three percutaneous electrolysis protocols were applied: Dose A (3 impulses x 3 seconds x 3 mA), Dose B (3 impulses x 3 seconds x 3 mA plus a three-needle bath at 1 mA up to 1,000 mJ), and Dose C (three-needle bath at 1 mA up to 14,000 mJ). The electrolytic effect was quantified using ultrasound image analysis at multiple time points: pre-treatment, immediately post-treatment, and at 0.5, 1, 2, 3, 4, 5, 10, 20, 30, 60, 360 (6h), 720 (12h), and 1,440 minutes (24h). Graphical inspection and curvilinear regression models were used to describe the temporal dynamics of each protocol.

Results

Dose A showed a stable, reproducible response, with a peak effect at 20 minutes (value: 5.60), followed by a gradual return to baseline at 360 minutes (6 hours). Dose B exhibited greater variability but returned to baseline by 360 minutes. Dose C revealed the greatest dispersion, with high peaks (8.50 at 20 minutes) and persistent negative values at 24 hours, without evidence of stabilization. Quadratic and cubic models provided the best fit for Dose A, while lower fitting was observed for Doses B and C.

Conclusions

The temporal pattern of the electrolytic effect varies notably depending on the protocol used. Quantitative ultrasound imaging provides an objective, non-invasive method for monitoring changes during percutaneous electrolysis therapy.

Zitieren

APA

Malo-Urriés, M., Rodríguez-Sanz, J., Borrella-Andrés, S., Albarova-Corral, I., Ríos-Asín, I., & López-de-Celis, C. (2025). Quantifying the Temporal Resolution of Gas-Induced Ultrasound Changes Following Percutaneous Electrolysis in Tendon Tissue. A Cadaveric Study. Invasive Physiotherapy and Musculoskeletal Medicine, 1(1), e17. https://doi.org/10.63360/ipmm.v1.e17

Vancouver

Malo-Urriés M, Rodríguez-Sanz J, Borrella-Andrés S, Albarova-Corral I, Ríos-Asín I, López-de-Celis C. Quantifying the Temporal Resolution of Gas-Induced Ultrasound Changes Following Percutaneous Electrolysis in Tendon Tissue. A Cadaveric Study. Invasive Physiotherapy and Musculoskeletal Medicine. 2025;1(1):e17. doi:10.63360/ipmm.v1.e17

BibTeX
@article{MaloUrris2025,
  author = {Malo-Urriés, Miguel and Rodríguez-Sanz, Jacobo and Borrella-Andrés, Sergio and Albarova-Corral, Isabel and Ríos-Asín, Izarbe and López-de-Celis, Carlos},
  title = {Quantifying the Temporal Resolution of Gas-Induced Ultrasound Changes Following Percutaneous Electrolysis in Tendon Tissue. A Cadaveric Study},
  journal = {Invasive Physiotherapy and Musculoskeletal Medicine},
  year = {2025},
  volume = {1},
  number = {1},
  pages = {e17},
  doi = {10.63360/ipmm.v1.e17}
}
Kostenlos starten →