The Effect of Increased Tube Tension in Head and Neck Scans on CTDIvol and Critical Organ Doses: A Monte Carlo-Based Evaluation
Advances in Medical Pyhsics and Applied Sciences · 2026
DOI: 10.63187/ampas.47 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advances in Medical Pyhsics and Applied Sciences, 2026. Verfasst von Turan ŞAHMARAN und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The aim of this study is to evaluate the effect of different tube voltage (kVp) values on organ doses in head and neck computed tomography (CT) protocols using a 3-month pregnant female phantom via the VirtualDose™CT software. Organ doses were simulated using VirtualDose™CT by selecting the GE LightSpeed Pro 16 scanner model. For the head and neck region, protocols were established at 80, 100, 120, and 140 kVp values with a constant collimation of 20 mm, a pitch of 1, and fixed mAs. CT dose index (CTDIvol) and organ doses (mGy) were obtained from the software reports for each kVp value. With the increase in kVp, CTDIvol values increased from 2.84 mGy at 80 kVp to 12.10 mGy at 140 kVp. A similar increase was observed in critical organ doses. The lens dose increased from 6.41 to 25.85 mGy, the thyroid dose from 1.87 to 7.42 mGy, and the brain dose from 3.58 to 17.77 mGy. For out-of-field regions, the uterus/cervix dose was observed in the range of 0.02–0.09 mGy, and the total fetus dose in the range of 0.01–0.05 mGy. Under constant mAs conditions, increasing kVp significantly increases CTDIvol and critical organ doses in the head and neck region. Although uterus/cervix and fetus doses remain at low levels in head and neck CT, they are influenced by technical parameters. Therefore, when a CT indication is unavoidable during pregnancy, protocol optimization is crucial to maintain diagnostic adequacy.
Zitieren
APA
ŞAHMARAN, T., & NUR, S. (2026). The Effect of Increased Tube Tension in Head and Neck Scans on CTDIvol and Critical Organ Doses: A Monte Carlo-Based Evaluation. Advances in Medical Pyhsics and Applied Sciences. https://doi.org/10.63187/ampas.47
Vancouver
ŞAHMARAN T, NUR S. The Effect of Increased Tube Tension in Head and Neck Scans on CTDIvol and Critical Organ Doses: A Monte Carlo-Based Evaluation. Advances in Medical Pyhsics and Applied Sciences. 2026. doi:10.63187/ampas.47
BibTeX
@article{AHMARAN2026,
author = {ŞAHMARAN, Turan and NUR, Süreyya},
title = {The Effect of Increased Tube Tension in Head and Neck Scans on CTDIvol and Critical Organ Doses: A Monte Carlo-Based Evaluation},
journal = {Advances in Medical Pyhsics and Applied Sciences},
year = {2026},
doi = {10.63187/ampas.47}
}
EUVIMED