AI-Assisted Monitoring and Feedback for Infection-Prevention Compliance in Emergency Nursing: a Quantitative Before and After Study
American Journal of Advanced Technology and Engineering Solutions · 03.12.2025 · 15 (12) · 72
DOI: 10.63125/nd3za281 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Advanced Technology and Engineering Solutions, online erschienen am 03.12.2025. Verfasst von Md Mohsin Bhuyain.
Abstract (Originalsprache)
This study evaluated the effectiveness of a computer vision–based monitoring system with real-time audiovisual feedback in improving infection prevention and control (IPC) compliance among emergency department nurses. Using a quantitative before-and-after design, 142 registered nurses were assessed across 4,820 clinical care opportunities, equally divided between baseline and post-intervention phases. Overall IPC compliance increased significantly from 58.38% to 84.11%, representing a 25.73-percentage-point improvement (p < 0.001), with notable gains in aseptic procedures (+29.63 percentage points), vascular barrier precautions (+30.56 percentage points), and high-acuity resuscitation settings (+31.57 percentage points). Early-career nurses demonstrated the greatest improvement (+32.37 percentage points), while day-to-night compliance disparities narrowed substantially. Multivariable analysis confirmed significantly higher post-intervention compliance (adjusted OR = 3.82; 95% CI: 3.28–4.45), and the proportion of nurses meeting the ≥80% compliance benchmark increased from 4.23% to 78.87%. Improvements remained stable throughout the eight-week observation period. These findings suggest that AI-enabled continuous monitoring with immediate feedback can substantially strengthen IPC adherence, reduce workflow-related disparities, and support patient safety in emergency nursing environments.
Zitieren
APA
Bhuyain, M. M. (2025). AI-Assisted Monitoring and Feedback for Infection-Prevention Compliance in Emergency Nursing: a Quantitative Before and After Study. American Journal of Advanced Technology and Engineering Solutions, 15(12), 72. https://doi.org/10.63125/nd3za281
Vancouver
Bhuyain MM. AI-Assisted Monitoring and Feedback for Infection-Prevention Compliance in Emergency Nursing: a Quantitative Before and After Study. American Journal of Advanced Technology and Engineering Solutions. 2025;15(12):72. doi:10.63125/nd3za281
BibTeX
@article{Bhuyain2025,
author = {Bhuyain, Md Mohsin},
title = {AI-Assisted Monitoring and Feedback for Infection-Prevention Compliance in Emergency Nursing: a Quantitative Before and After Study},
journal = {American Journal of Advanced Technology and Engineering Solutions},
year = {2025},
volume = {15},
number = {12},
pages = {72},
doi = {10.63125/nd3za281}
}
EUVIMED