EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Baseline Vapour Pressure Deficit Dynamics in an Emersed Anubias Cultivation Incubator: Sensor Construct Validity and Humidity-Governed VPD Drivers

Al Barra Harahap, Vera Khoirunnisa, Aprilia Siregar, Sintya Shety Simanjuntak

International Journal of Electrical Engineering, Mathematics and Computer Science · 30.06.2026 · 3 (2) · 01-12

DOI: 10.62951/ijeemcs.v3i2.390 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Electrical Engineering, Mathematics and Computer Science, online erschienen am 30.06.2026. Verfasst von Al Barra Harahap und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitieren

Abstract (Originalsprache)

Vapour pressure deficit (VPD) has gained recognition as a physiologically superior microclimate control variable in controlled-environment agriculture, yet no quantitative VPD characterisation exists for emersed cultivation of variegated Anubias barteri var. nana 'Pinto'. This study characterises the VPD microclimate of an ebb-and-flow cyber-physical incubator equipped with an MLX90614 infrared radiometric sensor, two calibrated DHT22 humidity sensors, a DS18B20 nutrient solution sensor, and an ESP32-S3 microcontroller. A 5.36-hour passive commissioning session yielded 1,884 valid data rows at a 10-second logging interval. The mean baseline was 0.703 ± 0.022 kPa, falling within the upper portion of the reference envelope inferred from available literature on emersed Anubias acclimatisation. Indoor relative humidity was identified as the dominant VPD driver (r = −0.695, R² = 0.483), while air temperature showed negligible association (r = −0.008), supporting mist actuation as the appropriate primary control strategy. The MLX90614 recorded a consistent radiometric offset of ΔT_rad = −1.61 ± 0.10 °C relative to indoor air temperature, reflecting the composite FOV average of cooler evaporative surfaces; the resulting was 0.327 kPa (32%) lower than the air-temperature-only estimate, demonstrating that the choice of surface temperature reference has a material effect on the computed VPD. A persistent ambient VPD gradient of +0.540 kPa was documented throughout the session, quantifying the continuous moisture gradient from the incubator interior to the ambient environment. These results establish a quantitative VPD baseline for emersed Anubias cultivation, define the construct validity boundaries of the sensor suite, and provide the empirical foundation for a companion closed-loop Fuzzy-PI VPD controller.

Zitieren

APA

Harahap, A. B., Khoirunnisa, V., Siregar, A., & Simanjuntak, S. S. (2026). Baseline Vapour Pressure Deficit Dynamics in an Emersed Anubias Cultivation Incubator: Sensor Construct Validity and Humidity-Governed VPD Drivers. International Journal of Electrical Engineering, Mathematics and Computer Science, 3(2), 01-12. https://doi.org/10.62951/ijeemcs.v3i2.390

Vancouver

Harahap AB, Khoirunnisa V, Siregar A, Simanjuntak SS. Baseline Vapour Pressure Deficit Dynamics in an Emersed Anubias Cultivation Incubator: Sensor Construct Validity and Humidity-Governed VPD Drivers. International Journal of Electrical Engineering, Mathematics and Computer Science. 2026;3(2):01-12. doi:10.62951/ijeemcs.v3i2.390

BibTeX
@article{Harahap2026,
  author = {Harahap, Al Barra and Khoirunnisa, Vera and Siregar, Aprilia and Simanjuntak, Sintya Shety},
  title = {Baseline Vapour Pressure Deficit Dynamics in an Emersed Anubias Cultivation Incubator: Sensor Construct Validity and Humidity-Governed VPD Drivers},
  journal = {International Journal of Electrical Engineering, Mathematics and Computer Science},
  year = {2026},
  volume = {3},
  number = {2},
  pages = {01--12},
  doi = {10.62951/ijeemcs.v3i2.390}
}
Kostenlos starten →