Kurz gefasst

Fachartikel in der Zeitschrift Revista Ingenio global, online erschienen am 19.07.2026. Verfasst von Darwin Mauricio Rodriguez Calala und 2 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Create a board to collect temperature signals to monitor the temperature in electrical transformers. This is a technological option to improve monitoring and preventive maintenance tactics. Methodology: Applied research was conducted with a quantitative approach and an experimental design in a laboratory. This research was based on the design, construction, and validation of a prototype that includes a PT100 resistive sensor, a Siemens AM2 analog expansion module, and a Siemens LOGO! 230 RCE programmable logic controller. The validation was done through simulation in LOGO! Thru simulation in LOGO! Soft Comfort and the functional tests in idle state involve verifying if the system turns on, identifying the analog module, processing 4–20 mA input signals, executing the program logic, and confirming that the system is powered on. The analog module must also be identified, process 4–20 mA input signals, execute the program logic, and verify communication between devices.

Results

The constructed board exhibited proper functioning. It was verified that the controller had an energy of 119.8 V. The AM2 module was automatically recognized. An input signal of 12.02 mA was processed, which corresponded to 100.3 °C. The output Q1 was activated by 119.6 V and there were no errors in internal communication.

Conclusions

The created prototype validated that the components work well together and created a platform that can grow for future thermal monitoring applications in power transformers. This can be expanded using SCADA systems, HMI interfaces, and technologies for remote data collection.

Zitieren

APA

Calala, D. M. R., Calala, C. H. R., & Morejón, K. I. T. (2026). Implementación y validación de un tablero para adquisición de señales térmicas orientado al monitoreo de transformadores. Revista Ingenio global, 5(2), 23-38. https://doi.org/10.62943/rig.v5n2.2026.568

Vancouver

Calala DMR, Calala CHR, Morejón KIT. Implementación y validación de un tablero para adquisición de señales térmicas orientado al monitoreo de transformadores. Revista Ingenio global. 2026;5(2):23-38. doi:10.62943/rig.v5n2.2026.568

BibTeX
@article{Calala2026,
  author = {Calala, Darwin Mauricio Rodriguez and Calala, Cristian Hernan Rodriguez and Morejón, Klever Iván Toapanta},
  title = {Implementación y validación de un tablero para adquisición de señales térmicas orientado al monitoreo de transformadores},
  journal = {Revista Ingenio global},
  year = {2026},
  volume = {5},
  number = {2},
  pages = {23--38},
  doi = {10.62943/rig.v5n2.2026.568}
}