EUVIMEDEUVIMED entdecken
Crossref

Tracheostomy Tube Monitoring Accessory to Detect Accidental Decannulation and Obstruction Emergencies in Ventilator-Independent Pediatric Patients

Kaylee Meyers, Quinton Burke, Arsalan Siddiqui, Habib Zalzal, Thomas Osmond, Keat Ghee Ong, Jules Sherman

Tracheostomy: Official Journal of the Global Tracheostomy Collaborative · 2024

DOI: 10.62905/001c.124445 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tracheostomy: Official Journal of the Global Tracheostomy Collaborative, 2024. Verfasst von Kaylee Meyers und 6 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Some of the leading causes of tracheostomy-related complications in pediatric populations are accidental decannulation and obstruction events that result in permanent neurological damage or death if not mitigated quickly enough. Despite the severity of tracheostomy tube emergency events, there is currently no effective medical technology available that can specifically detect accidental decannulation or obstruction in a tracheostomized patient that is not ventilator dependent. Therefore, a pediatric tracheal breathing model system was developed to assist with testing new tracheostomy tube technologies for identifying emergency events.

Methods

A custom carbon dioxide monitoring tracheostomy tube attachment was engineered to collect breathing waveform data during emergency events (e.g., improper insertion, accidental decannulation, and mucus obstruction). Anatomically accurate pediatric tracheal models for various age groups (0-3 months, 2-4 years, and 10-12 years old) were developed with modelling software and a 3D printer. A breathing simulator was integrated with the tracheal models to generate age-dependent respiration patterns during simulated tracheostomy tube emergencies.

Results

Carbon dioxide readings from the custom tracheostomy tube attachment indicated distinct waveform recordings during simulated tracheostomy tube emergency events for all age groups tested. During incorrect insertion, accidental decannulation, and complete blockage of a tracheostomy tube, exhaled carbon dioxide readings remained static at ambient levels. Partial mucus obstruction of a tracheostomy tube decreased exhaled carbon dioxide waveform amplitude relative to unobstructed conditions.

Conclusions

The tracheostomy tube attachment successfully recorded respiration patterns during simulated tracheostomy tube emergencies in pediatric patients of varying age. Breathing waveform data collected from the model system will aid in the development of emergency airway event detection software integrated in the tracheostomy tube sensing accessory.

Zitieren

APA

Meyers, K., Burke, Q., Siddiqui, A., Zalzal, H., Osmond, T., Ong, K. G., & Sherman, J. (2024). Tracheostomy Tube Monitoring Accessory to Detect Accidental Decannulation and Obstruction Emergencies in Ventilator-Independent Pediatric Patients. Tracheostomy: Official Journal of the Global Tracheostomy Collaborative. https://doi.org/10.62905/001c.124445

Vancouver

Meyers K, Burke Q, Siddiqui A, Zalzal H, Osmond T, Ong KG, et al. Tracheostomy Tube Monitoring Accessory to Detect Accidental Decannulation and Obstruction Emergencies in Ventilator-Independent Pediatric Patients. Tracheostomy: Official Journal of the Global Tracheostomy Collaborative. 2024. doi:10.62905/001c.124445

BibTeX
@article{Meyers2024,
  author = {Meyers, Kaylee and Burke, Quinton and Siddiqui, Arsalan and Zalzal, Habib and Osmond, Thomas and Ong, Keat Ghee and Sherman, Jules},
  title = {Tracheostomy Tube Monitoring Accessory to Detect Accidental Decannulation and Obstruction Emergencies in Ventilator-Independent Pediatric Patients},
  journal = {Tracheostomy: Official Journal of the Global Tracheostomy Collaborative},
  year = {2024},
  doi = {10.62905/001c.124445}
}
Kostenlos starten →