EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Clinical performance and safety profile of the RAM cannula as a non-invasive ventilation interface post-extubation: an observational study in preterm newborns

Johanna Acosta, Clara Juliana Chavarro, Malena Gravaglia Pippo, Lilibeth Mamani, Juan Carlos Vidal

SAP Health and Policy · 05.12.2025 · 5 · 426

DOI: 10.62486/shp2026426 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SAP Health and Policy, online erschienen am 05.12.2025. Verfasst von Johanna Acosta und 4 weiteren Autor:innen. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Non-invasive ventilation (NIV) is a fundamental strategy in the respiratory management of preterm infants. The RAM cannula is a binasal interface designed for positive pressure delivery, whose flexible, wide-bore design allows for effective support with a potentially lower risk of nasal injury. Despite its increasing use, evidence regarding its efficacy and safety in very low birth weight infants remains limited.

Objective

To describe the clinical performance and safety profile of the RAM cannula used as a post-extubation ventilatory support strategy in preterm infants, and to analyze the clinical and demographic factors associated with technique failure in our population.

Methods

An observational, analytical, and retrospective study was conducted, including preterm infants who used a RAM cannula as post-extubation ventilatory support during hospitalization. NIV failure was defined as the need for reintubation and return to invasive mechanical ventilation within the first 48 hours. Perinatal, respiratory, and safety variables were analyzed. Statistical analysis included Chi-square or Fisher's exact tests for categorical variables and Student's t-test for continuous variables (p < 0.05).

Results

Thirty-two newborns were included, with a mean gestational age of 28.1 ± 1.9 weeks and a birth weight of 1063 ± 179 g. The success rate of extubation using the RAM cannula was 81% (26/32). No significant differences were found in weight, gestational age, or Apgar scores between the success and failure groups. However, bivariate analysis revealed a statistically significant association between NIV failure and the presence of nasal lesions (33% in the failure group vs. 0% in the success group; p=0.002), intraventricular hemorrhage (33% vs. 0%; p=0.002), and Premature Rupture of Membranes ≥ 18 h (32% vs. 0%; p=0.003). The overall incidence of nasal lesions was low (6%).

Conclusions

With a failure rate of 19% and nasal injury at 6%, the RAM cannula could be an alternative among NIV interfaces to be considered for specific patients in units with high reintubation rates due to nasal trauma.

Zitieren

APA

Acosta, J., Chavarro, C. J., Pippo, M. G., Mamani, L., & Vidal, J. C. (2025). Clinical performance and safety profile of the RAM cannula as a non-invasive ventilation interface post-extubation: an observational study in preterm newborns. SAP Health and Policy, 5, 426. https://doi.org/10.62486/shp2026426

Vancouver

Acosta J, Chavarro CJ, Pippo MG, Mamani L, Vidal JC. Clinical performance and safety profile of the RAM cannula as a non-invasive ventilation interface post-extubation: an observational study in preterm newborns. SAP Health and Policy. 2025;5:426. doi:10.62486/shp2026426

BibTeX
@article{Acosta2025,
  author = {Acosta, Johanna and Chavarro, Clara Juliana and Pippo, Malena Gravaglia and Mamani, Lilibeth and Vidal, Juan Carlos},
  title = {Clinical performance and safety profile of the RAM cannula as a non-invasive ventilation interface post-extubation: an observational study in preterm newborns},
  journal = {SAP Health and Policy},
  year = {2025},
  volume = {5},
  pages = {426},
  doi = {10.62486/shp2026426}
}
Kostenlos starten →