EVALUATING PLATELET STORAGE LESION DYNAMICS AND MICRO VESICLE RELEASE IN COLD-STORED EXTENDED-LIFE PLATELET CONCENTRATES
Acta Innovations · 07.11.2026 · 64 (3s)
DOI: 10.62441/actainnovations.vi.3377 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Innovations, online erschienen am 07.11.2026.
Abstract (Originalsprache)
Background
Platelet concentrates (PCs) are generally kept at 20-24°C up to a limit of 5 to 7 days, primarily due to the development of the platelet storage lesion (PSL) and the risk of bacterial contamination. Data from the more recent literature indicate that it could be possible to keep the platelets for a longer duration at cold temperatures, between 1 and 6 °C, and even potentially maintain their hemostatic function, while EVs, also called micro vesicles (MVs), shed by platelets, could be markers of the platelet quality of the stored platelet products.
Aims
This review aims to collate evidence published between 2020 and 2025 on PSL behavior and EV release from cold-stored extended-life PCs and highlight gaps in current research and practice.
Methods
An inclusion criteria based structured narrative review was performed with 16 articles: 8 in vitro experimental papers, 1 clinical series, 4 reviews/comments, 3 regulatory/trial registry reports. Articles were selected based on targeted searching (October 2026) and included 8 in vitro experimental studies, 1 clinical series, 4 reviews/comments, 3 regulatory/trial registry articles. Study design, storage conditions, time points, markers and outcomes were extracted into tables and narratively synthesized (no new laboratory data).
Results
Platelet activation and degranulation and EV release increased with storage time under all conditions and at storage times 5 to 21 days, being slightly more EVs in room temperature cold-storage units compared to 20 days of cold storage were identified from day 4 and more EVs on day 15, with identical coagulation efficacy per EV. An analysis of 85 apheresis units showed increased platelet EVs from 5.11 ± 3.33 initially at collection to 8.73 ± 4.84 prior to transfusion, with no correlation to corrected count increment . Cold storage maintained clot retraction up to day 21 and >200 x 10^9 platelets/interim unit on day 21, but with more pre-activation. An increase in complement activation and HMGB1 was observed during storage with less activation with PAS than plasma.
Conclusions
EV release is a reproducible hallmark of storage lesion. In prolonged cold storage, EVs enlarge earlier, are more plentiful later, and retain their per vesicle procoagulant activity. EV metrics correlate with storage duration but have yet to be validated as translational predictors of efficacy, and the inflammatory burden of cold units beyond 15 days has not been quantified. Harmonized EV methodologies and clinical studies relating EV and activation parameters to recipient outcomes are desirable.
Zitieren
APA
(2026). EVALUATING PLATELET STORAGE LESION DYNAMICS AND MICRO VESICLE RELEASE IN COLD-STORED EXTENDED-LIFE PLATELET CONCENTRATES. Acta Innovations, 64(3s). https://doi.org/10.62441/actainnovations.vi.3377
Vancouver
EVALUATING PLATELET STORAGE LESION DYNAMICS AND MICRO VESICLE RELEASE IN COLD-STORED EXTENDED-LIFE PLATELET CONCENTRATES. Acta Innovations. 2026;64(3s). doi:10.62441/actainnovations.vi.3377
BibTeX
@article{euvimed2026,
title = {EVALUATING PLATELET STORAGE LESION DYNAMICS AND MICRO VESICLE RELEASE IN COLD-STORED EXTENDED-LIFE PLATELET CONCENTRATES},
journal = {Acta Innovations},
year = {2026},
volume = {64},
number = {3s},
doi = {10.62441/actainnovations.vi.3377}
}
EUVIMED