Análisis comparativo entre ionómero de vidrio y alcacites con pruebas de resistencia a la compresión. Un estudio in vitro
Revista Odontológica Stomarium · 15.04.2026 · 3 (3) · 31-52
DOI: 10.62407/pmw58x08 ↗Kurz gefasst
Fachartikel in der Zeitschrift Revista Odontológica Stomarium, online erschienen am 15.04.2026. Verfasst von Vernon Gabriel Narvaez Mairena und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Objective
To compare the compressive strength of the glass ionomer cement GC Fuji IX GP and Cention N (Ivoclar Vivadent) through in vitro testing using standardized specimens, to identify the material with superior mechanical performance. Methodology: A total of 40 standardized cylindrical specimens were prepared, with a height of 12 mm and a diameter of 6 mm, following each manufacturer’s specifications, and subsequently stored in distilled water. The samples were divided into two experimental groups: the first group consisted of 20 glass ionomer specimens, and the second group comprised 20 alkasite specimens. All samples were tested in a laboratory using a universal testing machine. A TRITECH50 50 kN (Wykeham Farrance, Controls Group) device was used to subject the 40 specimens to compressive strength testing.
Results
A statistically significant difference was found between the compressive strength values of the two materials (p < 0.001). The analysis clearly showed that the alkasite exhibited higher compressive strength (144.83 MPa) compared to the glass ionomer (40.98 MPa), with a large effect size (Cohen’s d = 5.53).
Conclusions
Cention N alkasite (Ivoclar Vivadent) demonstrated significantly higher compressive strength compared to GC Fuji IX GP glass ionomer, with a mean difference of approximately 104 MPa (p < 0.001).
Zitieren
APA
Mairena, V. G. N., García, K. E. M., Salinas, K. L. A., & Molina, I. G. M. (2026). Análisis comparativo entre ionómero de vidrio y alcacites con pruebas de resistencia a la compresión. Un estudio in vitro. Revista Odontológica Stomarium, 3(3), 31-52. https://doi.org/10.62407/pmw58x08
Vancouver
Mairena VGN, García KEM, Salinas KLA, Molina IGM. Análisis comparativo entre ionómero de vidrio y alcacites con pruebas de resistencia a la compresión. Un estudio in vitro. Revista Odontológica Stomarium. 2026;3(3):31-52. doi:10.62407/pmw58x08
BibTeX
@article{Mairena2026,
author = {Mairena, Vernon Gabriel Narvaez and García, Karla Elizabeth Malespín and Salinas, Kristell Lissette Arcia and Molina, Iracela Gabriela Matute},
title = {Análisis comparativo entre ionómero de vidrio y alcacites con pruebas de resistencia a la compresión. Un estudio in vitro},
journal = {Revista Odontológica Stomarium},
year = {2026},
volume = {3},
number = {3},
pages = {31--52},
doi = {10.62407/pmw58x08}
}
EUVIMED