Kurz gefasst

Fachartikel in der Zeitschrift Transactions on Computer Science and Intelligent Systems Research, online erschienen am 23.11.2026. Verfasst von Haoxiang Sun. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable electrocardiogram (ECG) devices need analog front-end (AFE) circuits that can detect microvolt-to-millivolt cardiac signals continuously for extended periods with very small batteries or harvested energy. The first amplification stage strongly influences total input-referred noise and therefore requires careful allocation of the power budget. This paper studies the engineering trade-off between input-referred noise and power consumption in low-power operational-amplifier-based ECG AFEs. This comparative literature review examines peer-reviewed designs published from 2015 to 2026 and draws on established work on chopper stabilization, auto-zero techniques, common-mode interference and wearable biosensing. The comparison includes power, integrated input-referred noise, gain, bandwidth, common-mode rejection ratio, input impedance and noise efficiency where reported. The results show that there is no single universally optimal AFE; the lowest-power designs reviewed here accept higher noise, and sub-microvolt noise generally requires microwatt-level power or more advanced circuit techniques. Chopper stabilization, current reuse, weak-inversion biasing, capacitive coupling and digitally assisted offset cancellation can be used to shift this trade-off, but each has its own disadvantages, such as ripple, reduced input impedance, bandwidth limitations, area or circuit complexity. Therefore, future wearable ECG AFEs should focus on adaptive, application-specific biasing and standardized multi-metric benchmarking rather than solely reducing power consumption or noise.

Zitieren

APA

Sun, H. (2026). Performance Trade-Off Analysis of Low-Power Wearable ECG Analog Front Ends. Transactions on Computer Science and Intelligent Systems Research, 14, 296-305. https://doi.org/10.62051/2m50r432

Vancouver

Sun H. Performance Trade-Off Analysis of Low-Power Wearable ECG Analog Front Ends. Transactions on Computer Science and Intelligent Systems Research. 2026;14:296-305. doi:10.62051/2m50r432

BibTeX
@article{Sun2026,
  author = {Sun, Haoxiang},
  title = {Performance Trade-Off Analysis of Low-Power Wearable ECG Analog Front Ends},
  journal = {Transactions on Computer Science and Intelligent Systems Research},
  year = {2026},
  volume = {14},
  pages = {296--305},
  doi = {10.62051/2m50r432}
}
Kostenlos starten →