EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Reletionship Between Ceiling Height and Ventilation Area With The Temperature and Humadity of The Dorm Room at Darul Hijrah Girls’ Islamic Boarding School

Nurilda Hidayati Kamilah, Junaidi, Yohanes Joko Supriyadi

Global Health & Environmental Perspectives · 05.07.2026 · 4 (1) · 661-669

DOI: 10.61848/ghep.v2i2.172 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Global Health & Environmental Perspectives, online erschienen am 05.07.2026. Verfasst von Nurilda Hidayati Kamilah und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Air quality in Islamic boarding school dormitories is often suboptimal due to overcrowding and substandard ventilation systems, which can pose health risks. Poor physical conditions in dormitory rooms impede air flow, creating a humid environment that can reduce productivity and affect the health of female students. This study aims to analyze the relationship between ceiling height and ventilation area with temperature and humidity in dormitory rooms at the Darul Hijrah Putri Islamic Boarding School. This type of research is quantitative, using a cross-sectional study design with a purposive sampling technique in 28 rooms based on active occupancy criteria. Data were analyzed using the Spearman Rank correlation test. The results showed that all rooms had ceiling heights that met the requirements (an average of 3.32 m) and were moderately positively correlated with temperature (r=0.433) and humidity (r=0.436). In contrast, 89.29% of rooms had inadequate ventilation, which showed a significant negative correlation with humidity (r=-0.424) but not with temperature. Although 96.43% of rooms met temperature requirements, 89.29% of rooms had humidity above the standard. In conclusion, the ceiling height is adequate, but the natural ventilation area needs to be increased and the layout of goods improved as well as the implementation of regular window opening to reduce high humidity and improve the quality of the female students' living environment.

Zitieren

APA

Kamilah, N. H., Junaidi, & Supriyadi, Y. J. (2026). The Reletionship Between Ceiling Height and Ventilation Area With The Temperature and Humadity of The Dorm Room at Darul Hijrah Girls’ Islamic Boarding School. Global Health & Environmental Perspectives, 4(1), 661-669. https://doi.org/10.61848/ghep.v2i2.172

Vancouver

Kamilah NH, Junaidi, Supriyadi YJ. The Reletionship Between Ceiling Height and Ventilation Area With The Temperature and Humadity of The Dorm Room at Darul Hijrah Girls’ Islamic Boarding School. Global Health & Environmental Perspectives. 2026;4(1):661-669. doi:10.61848/ghep.v2i2.172

BibTeX
@article{Kamilah2026,
  author = {Kamilah, Nurilda Hidayati and Junaidi and Supriyadi, Yohanes Joko},
  title = {The Reletionship Between Ceiling Height and Ventilation Area With The Temperature and Humadity of The Dorm Room at Darul Hijrah Girls’ Islamic Boarding School},
  journal = {Global Health & Environmental Perspectives},
  year = {2026},
  volume = {4},
  number = {1},
  pages = {661--669},
  doi = {10.61848/ghep.v2i2.172}
}
Kostenlos starten →