EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Evaluation of retention and wear of nylon versus polyether ketone ketone (PEKK) inserts for locator attachments retaining mandibular implant overdenture: A crossover study

Mohamed Elghandour, Fatma Fathe Mahanna, Gilan Altonbary

Mansoura Journal of Dentistry · 01.01.2025 · 12 (3)

DOI: 10.61793/2812-5479.1164 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mansoura Journal of Dentistry, online erschienen am 01.01.2025. Verfasst von Mohamed Elghandour und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective: assessment and comparison between the retention and surface wear of nylon and polyether ketone ketone (PEKK) inserts of locator attachments retaining mandibular implant overdenture. Materials and methods: For this research, six patients, completely edentulous,were selected; each participant had received mandibular implants in the canine regions on each side, followed by locator attachments. Using a crossover design, patients were randomly assigned to receive different mandibular overdentures as follows. 1) Implantretained overdenture with nylon inserts; 2) Implant-retained overdenture with PEKK inserts. Retention measurements were conducted at three-time intervals: T0 (after pickup), T3 (3 months post-insertion of overdenture)and T6 (6 months post-insertion of overdenture) using a force meter device. For the surface wear analysis, scanning electron microscopy (SEM) was used to scan both PEKK and nylon inserts at all three time points (T0, T3, and T6).

Results

The retentive forces of the nylon and PEKK inserts in the locator attachment system were shown to differ statistically significantly at different evaluation times. Compared to nylon inserts, PEKK inserts showed less wear and dimensional changes at (T3) and (T6). A comparative analysis of locator attachment systems revealed that the retention forces of PEKK and nylon inserts differed significantly across evaluation periods (p < 0.05). PEKK inserts exhibited superior performance, maintaining significantly greater retention stability while showing less surface wear and dimensional deformation at both(T3) and(T6)assessments compared to nylon counterparts.

Conclusions

PEKK inserts in locator attachment systems may offer more predictable and stable retention and wear resistance in contrast to the traditional nylon inserts.

Zitieren

APA

Elghandour, M., Mahanna, F. F., & Altonbary, G. (2025). Evaluation of retention and wear of nylon versus polyether ketone ketone (PEKK) inserts for locator attachments retaining mandibular implant overdenture: A crossover study. Mansoura Journal of Dentistry, 12(3). https://doi.org/10.61793/2812-5479.1164

Vancouver

Elghandour M, Mahanna FF, Altonbary G. Evaluation of retention and wear of nylon versus polyether ketone ketone (PEKK) inserts for locator attachments retaining mandibular implant overdenture: A crossover study. Mansoura Journal of Dentistry. 2025;12(3). doi:10.61793/2812-5479.1164

BibTeX
@article{Elghandour2025,
  author = {Elghandour, Mohamed and Mahanna, Fatma Fathe and Altonbary, Gilan},
  title = {Evaluation of retention and wear of nylon versus polyether ketone ketone (PEKK) inserts for locator attachments retaining mandibular implant overdenture: A crossover study},
  journal = {Mansoura Journal of Dentistry},
  year = {2025},
  volume = {12},
  number = {3},
  doi = {10.61793/2812-5479.1164}
}
Kostenlos starten →