EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Do different Cavity Preparation Designs Influence Fracture Resistance of CAD/CAM Fabricated Ceramic Inlay and Onlay?

Nabil Ayad Saleem, Ali Atef Elkaffas, Ashraf Ibrahim Ali, Salah Hasab Mahmoud

Mansoura Journal of Dentistry · 01.01.2023 · 11 (2) · 107-114

DOI: 10.61793/2812-5479.1121 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mansoura Journal of Dentistry, online erschienen am 01.01.2023. Verfasst von Nabil Ayad Saleem und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study evaluated the impact of various cavity preparation designs on fracture resistance of CAD/CAM ceramic inlays and onlays. Materials and methods: Forty-eight teeth were randomly assigned to six groups (n=8): (group A) inlays with 75% width of the inter-cuspal distance (ICD, buccal cusp tip-to-palatal cusp tip), (group B) inlays with 100% width of the ICD, (Group C) onlays that had a palatal cusp reduction of 2.0 mm (functional cusp) and 75% width of ICD, (Group D) had a palatal cusp reduction of 2.0 mm (functional cusp) with 100% width of ICD,(Group E) had a palatal cusp reduction of 2.0 mm (functional cusp) and a buccal cusp reduction of 1.5mm (non-functional cusp) and 75% width of ICD, and (Group F) had palatal cusp reduction of 2.0 mm (functional cusp) and had buccal cusp reduction of 1.5mm (non-functional cusp) and 100% width of ICD. The fracture resistance of each group was measured using a universal testing machine. Data were statistically analyzed using the Shapiro-Wilk, one-way ANOVA, and post-hoc Tukey tests.

Results

One-way ANOVA revealed statistically non-significant differences among the tested groups at (p Conclusions: The various types of preparation designs had no significant difference in fracture resistance except for inlays with 75% width of ICD.

Zitieren

APA

Saleem, N. A., Elkaffas, A. A., Ali, A. I., & Mahmoud, S. H. (2023). Do different Cavity Preparation Designs Influence Fracture Resistance of CAD/CAM Fabricated Ceramic Inlay and Onlay?. Mansoura Journal of Dentistry, 11(2), 107-114. https://doi.org/10.61793/2812-5479.1121

Vancouver

Saleem NA, Elkaffas AA, Ali AI, Mahmoud SH. Do different Cavity Preparation Designs Influence Fracture Resistance of CAD/CAM Fabricated Ceramic Inlay and Onlay?. Mansoura Journal of Dentistry. 2023;11(2):107-114. doi:10.61793/2812-5479.1121

BibTeX
@article{Saleem2023,
  author = {Saleem, Nabil Ayad and Elkaffas, Ali Atef and Ali, Ashraf Ibrahim and Mahmoud, Salah Hasab},
  title = {Do different Cavity Preparation Designs Influence Fracture Resistance of CAD/CAM Fabricated Ceramic Inlay and Onlay?},
  journal = {Mansoura Journal of Dentistry},
  year = {2023},
  volume = {11},
  number = {2},
  pages = {107--114},
  doi = {10.61793/2812-5479.1121}
}
Kostenlos starten →