EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Direct versus indirect pick up of the locator retentive caps for two implant supported mandibular over denture: (a cross over study)

Christine Raouf Micheal Ibrahim, Amany Awad Elsayed Awad, Ahmed Ali Abdelrahman Habib

Mansoura Journal of Dentistry · 01.01.2023 · 10 (4) · 339-346

DOI: 10.61793/2812-5479.1107 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mansoura Journal of Dentistry, online erschienen am 01.01.2023. Verfasst von Christine Raouf Micheal Ibrahim und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

This study aimed to compare and calibrate the clinical retention of direct versus indirect pick of locator attachment retentive caps used to retain mandibular overdentures connected to two implants installed in the canine regions. Material and Methods: Ten patients received two implants in the canine areas of the mandible. According to the pick-up technique of the retentive caps and the color of the retentive inserts of locator attachments; the mandibular overdentures were classified into four groups as follows: Group I: Overdentures with locator retentive caps and blue inserts were picked up by indirect method. Group II: Overdentures with locator retentive caps and pink inserts were picked up by indirect method. Group III: Overdentures with locator retentive caps and blue inserts were picked up by direct method. Group IV: Overdentures with locator retentive caps and pink inserts were picked up by direct method.

Results

Calibration of the manufacturer retention values using force meter device mounted to a holder device revealed up to 91. 25 % to 95% accuracy of the retentive values measured in this study. A statistically significant difference in retentive scores was found between all inserts picked up directly or indirectly as verified by Kruskal Wallis Test except between Group II and Group IV( P=.061) and between Group I and Group III( P=.061)where no statistically significant difference in retention was found.

Conclusions

Laboratory (indirect) pick-up assembly of the locator attachments could be considered the technique of choice to avoid the difficulties of the direct pick-up procedures.

Zitieren

APA

Ibrahim, C. R. M., Awad, A. A. E., & Habib, A. A. A. (2023). Direct versus indirect pick up of the locator retentive caps for two implant supported mandibular over denture: (a cross over study). Mansoura Journal of Dentistry, 10(4), 339-346. https://doi.org/10.61793/2812-5479.1107

Vancouver

Ibrahim CRM, Awad AAE, Habib AAA. Direct versus indirect pick up of the locator retentive caps for two implant supported mandibular over denture: (a cross over study). Mansoura Journal of Dentistry. 2023;10(4):339-346. doi:10.61793/2812-5479.1107

BibTeX
@article{Ibrahim2023,
  author = {Ibrahim, Christine Raouf Micheal and Awad, Amany Awad Elsayed and Habib, Ahmed Ali Abdelrahman},
  title = {Direct versus indirect pick up of the locator retentive caps for two implant supported mandibular over denture: (a cross over study)},
  journal = {Mansoura Journal of Dentistry},
  year = {2023},
  volume = {10},
  number = {4},
  pages = {339--346},
  doi = {10.61793/2812-5479.1107}
}
Kostenlos starten →