Comparison between conventional and 3D printed implant retained mandibular complete overdentures regarding occlusion using digital occlusion analysis system (A pilot study)
Mansoura Journal of Dentistry · 01.01.2023 · 10 (3) · 169-177
DOI: 10.61793/2812-5479.1001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Mansoura Journal of Dentistry, online erschienen am 01.01.2023. Verfasst von Hazem M. M. Al-Sappagh und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
This within-patient study aimed to compare two different construction techniques (conventional and 3D printing) of two implant-assisted complete mandibular overdenture regarding occlusion using a digital occlusion analysis system (Occlusense).
Methods
Six patients were selected for this study from the prosthetic department, Faculty of Dentistry, Mansoura University. All patients received mandibular implant-assisted overdentures with two fabrication techniques, conventional overdenture (group I) and 3D printed overdenture (group II). Ball and socket attachments were used to retain the mandibular overdentures to the underlying implant fixtures. Conventional and 3D printed mandibular overdentures were compared and evaluated after 3 months of overdenture use regarding occlusion using occlusesnse.
Results
There was a significant difference in the evenness of occlusal force distribution between both groups over time from T0 to T3 (P=0.046 anterior, 0.037 and 0.043 premolars right and left) with more even occlusal force distribution in (group II) (x=8, 6 anterior right and left, x=-8 premolars) than in (group I) (x=3, 2 anterior right and left x=-1 premolars).
Conclusion
Within the limitation of this study, it was shown that implant overdentures constructed by 3D printing technique offer promising results compared to conventionally constructed implant overdentures regarding occlusal force distribution
Zitieren
APA
Al-Sappagh, H. M. M., Taha, M. S., Mansour, N. A., & Emera, R. M. (2023). Comparison between conventional and 3D printed implant retained mandibular complete overdentures regarding occlusion using digital occlusion analysis system (A pilot study). Mansoura Journal of Dentistry, 10(3), 169-177. https://doi.org/10.61793/2812-5479.1001
Vancouver
Al-Sappagh HMM, Taha MS, Mansour NA, Emera RM. Comparison between conventional and 3D printed implant retained mandibular complete overdentures regarding occlusion using digital occlusion analysis system (A pilot study). Mansoura Journal of Dentistry. 2023;10(3):169-177. doi:10.61793/2812-5479.1001
BibTeX
@article{AlSappagh2023,
author = {Al-Sappagh, Hazem M. M. and Taha, Mohamed S.N. and Mansour, Noha A. and Emera, Radwa M.K.},
title = {Comparison between conventional and 3D printed implant retained mandibular complete overdentures regarding occlusion using digital occlusion analysis system (A pilot study)},
journal = {Mansoura Journal of Dentistry},
year = {2023},
volume = {10},
number = {3},
pages = {169--177},
doi = {10.61793/2812-5479.1001}
}