EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

NON-CONTACT HEALTH MONITORING SYSTEM BASED ON MILLIMETER-WAVE RADAR

XiangRui Tang, Qian Guo, Dong Shen

Journal of Pharmaceutical and Medical Research · 30.07.2026 · 8 (4) · 17-22

DOI: 10.61784/jpmr3087 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Pharmaceutical and Medical Research, online erschienen am 30.07.2026. Verfasst von XiangRui Tang und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the expansion of the companion-animal market, animal protection, health management and harmonious coexistence between animals and humans have become increasingly important. The source project designs a portable embedded vital-sign monitoring system based on millimeter-wave radar. The system uses the IWR6843AOPEVM FMCW radar to collect raw physiological data, extracts heart-rate and respiration information through signal processing, displays the results on an OLED module, and transmits the data wirelessly to an upper computer such as a smartphone. Three domestic Doberman Pinschers were selected as test subjects, and heart-rate and respiration data were collected across daily states. Non-parametric testing, Spearman correlation, decision-tree classification, reliability analysis and validity analysis were used to evaluate the experimental data and product feedback. The condensed results show that the system has non-contact, real-time and portable monitoring advantages. Heart rate is the main basis for state classification, the decision-tree model performs well, and questionnaire analysis indicates that continuous working time and portability are the user concerns that require further optimization.

Zitieren

APA

Tang, X., Guo, Q., & Shen, D. (2026). NON-CONTACT HEALTH MONITORING SYSTEM BASED ON MILLIMETER-WAVE RADAR. Journal of Pharmaceutical and Medical Research, 8(4), 17-22. https://doi.org/10.61784/jpmr3087

Vancouver

Tang X, Guo Q, Shen D. NON-CONTACT HEALTH MONITORING SYSTEM BASED ON MILLIMETER-WAVE RADAR. Journal of Pharmaceutical and Medical Research. 2026;8(4):17-22. doi:10.61784/jpmr3087

BibTeX
@article{Tang2026,
  author = {Tang, XiangRui and Guo, Qian and Shen, Dong},
  title = {NON-CONTACT HEALTH MONITORING SYSTEM BASED ON MILLIMETER-WAVE RADAR},
  journal = {Journal of Pharmaceutical and Medical Research},
  year = {2026},
  volume = {8},
  number = {4},
  pages = {17--22},
  doi = {10.61784/jpmr3087}
}
Kostenlos starten →