EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

An in-house technique for direct identification of bacteria from positive blood cultures using MALDI-TOF MS

Nida Safdar, Aqib Sultan, Nasrullah Malik, Saira Saleem, Summiya Nizamuddin

Infectious Diseases Journal of Pakistan · 30.03.2026 · 35 (1) · 56-62

DOI: 10.61529/idjp.v35i1.480 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Infectious Diseases Journal of Pakistan, online erschienen am 30.03.2026. Verfasst von Nida Safdar und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Rapid identification of pathogens from positive blood cultures is crucial for timely antibiotic therapy and effective antimicrobial stewardship. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) enables early organism identification when applied directly to blood culture broth. This study evaluated a simplified, low-cost, in-house direct MALDI-TOF method and compared its diagnostic performance with the standard colony-based approach. Materials and Methods: This prospective study was conducted at the Microbiology Section of Shaukat Khanum Memorial Cancer Hospital & Research Centre, Lahore, from February to July 2025. One hundred positive blood cultures detected by the BACT/ALERT VIRTUO® system were included. Each specimen underwent both conventional post-culture MALDI-TOF MS identification and an in-house direct method using separator-gel tube centrifugation followed by saline washing. Genus- and species-level concordance between the two methods was calculated.

Results

Overall species-level and genus-level concordance were 60% and 66%, respectively. Gram-negative rods demonstrated the highest species-level accuracy (77.2%), whereas Gram-positive rods showed no species-level identification. Anaerobic bottles achieved higher accuracy (species: 67.3%, genus: 72.7%) than aerobic bottles (species: 51.1%, genus: 57.8%). Excellent agreement was observed for Klebsiella pneumoniae, Pseudomonas aeruginosa, Proteus mirabilis, and Acinetobacter baumannii, while coagulase-negative staphylococci and Enterococcus species exhibited lower identification rates.

Conclusion

The in-house MALDI-TOF method gave rapid, reliable, and cost-effective identification of Gram-negative bacteria, reducing turnaround time. Enhanced performance for Gram-positive identification can be achieved by incorporating detergent-assisted extraction. Integration of direct MALDI-TOF into routine workflows may support quick reporting and targeted therapy. Keywords: Antimicrobial stewardship, Blood culture, MALDI-TOF MS, Rapid bacterial identification

Zitieren

APA

Safdar, N., Sultan, A., Malik, N., Saleem, S., & Nizamuddin, S. (2026). An in-house technique for direct identification of bacteria from positive blood cultures using MALDI-TOF MS. Infectious Diseases Journal of Pakistan, 35(1), 56-62. https://doi.org/10.61529/idjp.v35i1.480

Vancouver

Safdar N, Sultan A, Malik N, Saleem S, Nizamuddin S. An in-house technique for direct identification of bacteria from positive blood cultures using MALDI-TOF MS. Infectious Diseases Journal of Pakistan. 2026;35(1):56-62. doi:10.61529/idjp.v35i1.480

BibTeX
@article{Safdar2026,
  author = {Safdar, Nida and Sultan, Aqib and Malik, Nasrullah and Saleem, Saira and Nizamuddin, Summiya},
  title = {An in-house technique for direct identification of bacteria from positive blood cultures using MALDI-TOF MS},
  journal = {Infectious Diseases Journal of Pakistan},
  year = {2026},
  volume = {35},
  number = {1},
  pages = {56--62},
  doi = {10.61529/idjp.v35i1.480}
}
Kostenlos starten →