EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

CFD analysis of photovoltaic panel performance under variable weather conditions with natural and forced convective cooling

Ayaz Aydin Abduljabbar, Manar Mohammed, Zahraa H. Mohammed Ali, Hussein Hayder Mohammed Ali, Furqan Haider Mohammed Ali, Timur Choban Khidir

International Journal of Renewable Energy Development · 01.07.2026 · 15 (4) · 808-817

DOI: 10.61435/ijred.2026.62339 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Renewable Energy Development, online erschienen am 01.07.2026. Verfasst von Ayaz Aydin Abduljabbar und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The objective of this study is to numerically investigate the influence of climatic conditions, particularly ambient temperature and relative humidity, on the thermal and electrical performance of photovoltaic (PV) panels, and to evaluate the effectiveness of natural and forced convection cooling for both conventional and finned panel configurations. A multilevel computational fluid dynamics (CFD) model was developed using ANSYS Fluent 16.1 under realistic environmental conditions of Baghdad, Iraq. Two configurations were examined: a conventional flat panel and a modified panel equipped with longitudinal fins acting as a passive heat sink. Under both natural and forced convection, with an inlet air velocity of 1.5 m/s for forced cooling, the simulations took into account solar radiation, species transport to capture humidity effects, and the k–ω turbulence model. Under natural convection, the traditional panel attained a maximum surface temperature of 333.11 K with an electrical efficiency of 27.8%; forced convection lowered the temperature to 319.22 K and increased efficiency to 29.88% (7.5% improvement). Under natural cooling, the finned design lowered the temperature to 327.4 K, raising the efficiency to 28.66% (~3% increase). Under forced cooling, it further dropped to 315.5 K, reaching a maximum efficiency of 30.43%. This translates to advancements of 9.4% over the traditional natural cooling scenario and 6.17% over the finned natural cooling scenario. Yearly average results show that the finned design improves electrical efficiency by about 2% under natural convection and up to 6.53% under forced convection, whereas forced cooling of the conventional panel gives a 3.12% increase. The enhancement is primarily attributed to increased heat transfer surface area and improved convective mixing, particularly under natural convection where fin-induced vortices significantly enhance heat dissipation.

Zitieren

APA

Abduljabbar, A. A., Mohammed, M., Ali, Z. H. M., Ali, H. H. M., Ali, F. H. M., & Khidir, T. C. (2026). CFD analysis of photovoltaic panel performance under variable weather conditions with natural and forced convective cooling. International Journal of Renewable Energy Development, 15(4), 808-817. https://doi.org/10.61435/ijred.2026.62339

Vancouver

Abduljabbar AA, Mohammed M, Ali ZHM, Ali HHM, Ali FHM, Khidir TC. CFD analysis of photovoltaic panel performance under variable weather conditions with natural and forced convective cooling. International Journal of Renewable Energy Development. 2026;15(4):808-817. doi:10.61435/ijred.2026.62339

BibTeX
@article{Abduljabbar2026,
  author = {Abduljabbar, Ayaz Aydin and Mohammed, Manar and Ali, Zahraa H. Mohammed and Ali, Hussein Hayder Mohammed and Ali, Furqan Haider Mohammed and Khidir, Timur Choban},
  title = {CFD analysis of photovoltaic panel performance under variable weather conditions with natural and forced convective cooling},
  journal = {International Journal of Renewable Energy Development},
  year = {2026},
  volume = {15},
  number = {4},
  pages = {808--817},
  doi = {10.61435/ijred.2026.62339}
}
Kostenlos starten →