Assessment of the Influence of Exposure Parameters on the Diagnostic Quality of Chest Radiographs at National Orthopaedic Hospital, Enugu

Ugwuja Mabel Chikodili, Okechukwu Sixtus Oluebube, Asogwa Toochukwu Loveth, Cletus Uche Eze, Charles Ugwoke Eze, Eberechukwu Nwakego Mokwuah

International Journal of Medical and Health Research · 30.05.2026 · 4 (2) · 105-115

DOI: 10.61424/ijmhr.v4i2.829 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Medical and Health Research, online erschienen am 30.05.2026. Verfasst von Ugwuja Mabel Chikodili und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chest radiography is an essential diagnostic tool in the detection and management of cardiopulmonary and thoracic pathologies, especially in orthopaedic settings like the National Orthopaedic Hospital, Enugu (NOHE). The quality of chest radiographs is largely influenced by the appropriate selection of exposure parameters, specifically kilovoltage peak (kVp), milliampere-seconds (mAs), and source-to-image distance (SID). However, the effect of these parameters on image quality at NOHE has not been extensively studied. This study aimed to assess how variations in kVp, mAs, and SID influence the diagnostic quality of chest radiographs performed at NOHE. A descriptive, cross-sectional study was conducted on 200 chest radiographs randomly selected from routine clinical practice. Diagnostic quality was assessed using four indicators: contrast, density, sharpness, and artifacts, all rated on a 5-point Likert scale. The study found that higher kVp (above 110), appropriate mAs (4.0–5.0), and longer SID (>180 cm) were associated with significantly improved contrast, density, sharpness, and fewer artifacts. Multiple regression analysis indicated that kVp and mAs were the strongest predictors of overall image quality. Mismanagement of exposure parameters, such as low kVp with high mAs or excessive SID, significantly decreased image quality and increased the presence of artifacts. The findings emphasize the need for standardizing exposure protocols and enhancing training for radiographers to ensure optimal image quality and minimize patient radiation exposure.

Zitieren

APA

Chikodili, U. M., Oluebube, O. S., Loveth, A. T., Eze, C. U., Eze, C. U., & Mokwuah, E. N. (2026). Assessment of the Influence of Exposure Parameters on the Diagnostic Quality of Chest Radiographs at National Orthopaedic Hospital, Enugu. International Journal of Medical and Health Research, 4(2), 105-115. https://doi.org/10.61424/ijmhr.v4i2.829

Vancouver

Chikodili UM, Oluebube OS, Loveth AT, Eze CU, Eze CU, Mokwuah EN. Assessment of the Influence of Exposure Parameters on the Diagnostic Quality of Chest Radiographs at National Orthopaedic Hospital, Enugu. International Journal of Medical and Health Research. 2026;4(2):105-115. doi:10.61424/ijmhr.v4i2.829

BibTeX
@article{Chikodili2026,
  author = {Chikodili, Ugwuja Mabel and Oluebube, Okechukwu Sixtus and Loveth, Asogwa Toochukwu and Eze, Cletus Uche and Eze, Charles Ugwoke and Mokwuah, Eberechukwu Nwakego},
  title = {Assessment of the Influence of Exposure Parameters on the Diagnostic Quality of Chest Radiographs at National Orthopaedic Hospital, Enugu},
  journal = {International Journal of Medical and Health Research},
  year = {2026},
  volume = {4},
  number = {2},
  pages = {105--115},
  doi = {10.61424/ijmhr.v4i2.829}
}
Kostenlos starten →