Comparative Evaluation of Radiation Dose Parameters in Digital Breast Tomosynthesis and Full-Field Digital Mammography Across Breast Density Categories: A Retrospective Study from Pakistan
European Journal of Clinical Pharmacy · 25.12.2025 · 7 (1) · 9005-9015
DOI: 10.61336/ejcp/25-08-614 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Clinical Pharmacy, online erschienen am 25.12.2025. Verfasst von Sana Shaikh.
Abstract (Originalsprache)
Digital Breast Tomosynthesis (DBT) has emerged as an advanced imaging modality with improved diagnostic accuracy over Full-Field Digital Mammography (FFDM), particularly in dense breast tissue. However, concerns persist regarding increased radiation exposure associated with DBT.Objective:To compare radiation dose parameters—Average Glandular Dose (AGD), Entrance Surface Dose (ESD), and Exposure Index (EI)—between DBT and FFDM across different breast density categories in a Pakistani population.Methods:This retrospective observational study analyzed 1,600 mammographic images from 200 female patients (December 2018–December 2022). All patients underwent bilateral imaging in COMBO mode using a Hologic Selenia Dimensions system. Breast density was categorized according to the American College of Radiology (ACR) classification (A–D). Radiation parameters (AGD, ESD, EI) were evaluated for both modalities in craniocaudal (CC) and mediolateral oblique (MLO) views. Statistical analysis was performed using SPSS version 22.0, with p
Zitieren
APA
Shaikh, S. (2025). Comparative Evaluation of Radiation Dose Parameters in Digital Breast Tomosynthesis and Full-Field Digital Mammography Across Breast Density Categories: A Retrospective Study from Pakistan. European Journal of Clinical Pharmacy, 7(1), 9005-9015. https://doi.org/10.61336/ejcp/25-08-614
Vancouver
Shaikh S. Comparative Evaluation of Radiation Dose Parameters in Digital Breast Tomosynthesis and Full-Field Digital Mammography Across Breast Density Categories: A Retrospective Study from Pakistan. European Journal of Clinical Pharmacy. 2025;7(1):9005-9015. doi:10.61336/ejcp/25-08-614
BibTeX
@article{Shaikh2025,
author = {Shaikh, Sana},
title = {Comparative Evaluation of Radiation Dose Parameters in Digital Breast Tomosynthesis and Full-Field Digital Mammography Across Breast Density Categories: A Retrospective Study from Pakistan},
journal = {European Journal of Clinical Pharmacy},
year = {2025},
volume = {7},
number = {1},
pages = {9005--9015},
doi = {10.61336/ejcp/25-08-614}
}
EUVIMED