Abstract (Originalsprache)

Digital Breast Tomosynthesis (DBT) has emerged as an advanced imaging modality with improved diagnostic accuracy over Full-Field Digital Mammography (FFDM), particularly in dense breast tissue. However, concerns persist regarding increased radiation exposure associated with DBT.Objective:To compare radiation dose parameters—Average Glandular Dose (AGD), Entrance Surface Dose (ESD), and Exposure Index (EI)—between DBT and FFDM across different breast density categories in a Pakistani population.Methods:This retrospective observational study analyzed 1,600 mammographic images from 200 female patients (December 2018–December 2022). All patients underwent bilateral imaging in COMBO mode using a Hologic Selenia Dimensions system. Breast density was categorized according to the American College of Radiology (ACR) classification (A–D). Radiation parameters (AGD, ESD, EI) were evaluated for both modalities in craniocaudal (CC) and mediolateral oblique (MLO) views. Statistical analysis was performed using SPSS version 22.0, with p

Zitieren

APA

Shaikh, S. (2025). Comparative Evaluation of Radiation Dose Parameters in Digital Breast Tomosynthesis and Full-Field Digital Mammography Across Breast Density Categories: A Retrospective Study from Pakistan. European Journal of Clinical Pharmacy, 7(1), 9005-9015. https://doi.org/10.61336/ejcp/25-08-614

Vancouver

Shaikh S. Comparative Evaluation of Radiation Dose Parameters in Digital Breast Tomosynthesis and Full-Field Digital Mammography Across Breast Density Categories: A Retrospective Study from Pakistan. European Journal of Clinical Pharmacy. 2025;7(1):9005-9015. doi:10.61336/ejcp/25-08-614

BibTeX
@article{Shaikh2025,
  author = {Shaikh, Sana},
  title = {Comparative Evaluation of Radiation Dose Parameters in Digital Breast Tomosynthesis and Full-Field Digital Mammography Across Breast Density Categories: A Retrospective Study from Pakistan},
  journal = {European Journal of Clinical Pharmacy},
  year = {2025},
  volume = {7},
  number = {1},
  pages = {9005--9015},
  doi = {10.61336/ejcp/25-08-614}
}
Kostenlos starten →