The Use of a Customized Acrylic Resin Stent to Stabilize a Free Gingival Autograft within the Distobuccal Area of a Mandibular Second Molar with High Degree of Muscle Attachment
臺灣牙周病醫學會雜誌 · 01.06.2015 · 20 (2) · 140-146
DOI: 10.6121/tap.2015.20.2.07 ↗Kurz gefasst
Fachartikel in der Zeitschrift 臺灣牙周病醫學會雜誌, erschienen am 01.06.2015. Verfasst von Yuan-Min Wang und 4 weiteren Autor:innen.
Abstract (Originalsprache)
An unfavorably high degree of muscle attachment in the distobuccal area of a mandibular second molar usually results from an inappropriate suture method after third molar extraction. This may lead to interference during subsequent periodontal surgery, such as guided tissue regeneration and crown lengthening procedures. How to correct such muscle attachment and bring about the release muscle fibers simultaneously is always a challenge for dentists. A number of methods have been proposed to improve such soft tissue morphology, but no method satisfies all clinical conditions. In this case report, a simple, low-cost and effective device to stabilize a free gingival autograft and bring about space maintenance by increasing vestibular depth was introduced. A clinical case is presented in which a satisfactory treatment outcome was achieved based on one year of follow-up. The vestibule on the distobuccal area of a mandibular second molar was increased by 7 mm in width and the keratinized gingiva was also increased. This new innovation may help to solve problems that are associated with inadequate keratinized gingiva and vestibular depth.
Schlagwörter
Zitieren
APA
Wang, Y., Ju, Y., Wu, T., Pan, W., & Chan, C. (2015). The Use of a Customized Acrylic Resin Stent to Stabilize a Free Gingival Autograft within the Distobuccal Area of a Mandibular Second Molar with High Degree of Muscle Attachment. 臺灣牙周病醫學會雜誌, 20(2), 140-146. https://doi.org/10.6121/tap.2015.20.2.07
Vancouver
Wang Y, Ju Y, Wu T, Pan W, Chan C. The Use of a Customized Acrylic Resin Stent to Stabilize a Free Gingival Autograft within the Distobuccal Area of a Mandibular Second Molar with High Degree of Muscle Attachment. 臺灣牙周病醫學會雜誌. 2015;20(2):140-146. doi:10.6121/tap.2015.20.2.07
BibTeX
@article{Wang2015,
author = {Wang, Yuan-Min and Ju, Yuh‐Ren and Wu, Tina and Pan, Whei‐Lin and Chan, Chiu‐Po},
title = {The Use of a Customized Acrylic Resin Stent to Stabilize a Free Gingival Autograft within the Distobuccal Area of a Mandibular Second Molar with High Degree of Muscle Attachment},
journal = {臺灣牙周病醫學會雜誌},
year = {2015},
volume = {20},
number = {2},
pages = {140--146},
doi = {10.6121/tap.2015.20.2.07}
}
EUVIMED