EUVIMEDEUVIMED entdecken
Crossref

Efficacy of visual double-lumen bronchial catheter in teaching lung isolation

Minhao Zhang, Halisa Paerhati, Miao Zhou, Jiahui Chen, Zhiyan Wang, Lianbing Gu, Pengyi Li

Progress in Medical Education · 2025

DOI: 10.61189/937243auxvcj ↗

Kurz gefasst

Fachartikel in der Zeitschrift Progress in Medical Education, 2025. Verfasst von Minhao Zhang und 6 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess the effectiveness of a visual double-lumen bronchial catheter in teaching lung isolation skills to anesthesia resident trainees.

Methods

Between September 2023 and September 2024, 20 anesthesiology residents from Jiangsu Cancer Hospital were randomly divided into two groups: the visual double-lumen group (n=10) and the conventional double-lumen group (n=10). Randomization was achieved using a random number table. The study assessed several outcomes, including total intubation time, positioning time, one-time intubation success rate, intraoperative catheter displacement rate, surgeon satisfaction scores, and the incidence of postoperative complications (pharyngeal pain, hoarseness, and dry cough) within 24 hours.

Results

The visual double-lumen group demonstrated superior results compared to the conventional double-lumen group in the following measures: total intubation time (70.2±11.8 s vs 224.9±35.6 s), positioning time (30.1±5.7s vs 176.6±26.4 s), one-time intubation success rate (85% vs 45%), intraoperative catheter displacement rate (10% vs 40%), surgeon’s intubation satisfaction score (8.10±1.07 vs 6.90±1.41), satisfaction score for pulmonary isolation (8.35±1.04 vs 6.55±1.36), and airway management satisfaction score (8.40±1.3 vs 6.70±1.34). Additionally, the incidence of postoperative pharyngeal pain (15% vs 45%), hoarseness (10% vs 40%), and dry cough (5% vs 35%) was significantly lower in the visual double-lumen group (all P

Zitieren

APA

Zhang, M., Paerhati, H., Zhou, M., Chen, J., Wang, Z., Gu, L., & Li, P. (2025). Efficacy of visual double-lumen bronchial catheter in teaching lung isolation. Progress in Medical Education. https://doi.org/10.61189/937243auxvcj

Vancouver

Zhang M, Paerhati H, Zhou M, Chen J, Wang Z, Gu L, et al. Efficacy of visual double-lumen bronchial catheter in teaching lung isolation. Progress in Medical Education. 2025. doi:10.61189/937243auxvcj

BibTeX
@article{Zhang2025,
  author = {Zhang, Minhao and Paerhati, Halisa and Zhou, Miao and Chen, Jiahui and Wang, Zhiyan and Gu, Lianbing and Li, Pengyi},
  title = {Efficacy of visual double-lumen bronchial catheter in teaching lung isolation},
  journal = {Progress in Medical Education},
  year = {2025},
  doi = {10.61189/937243auxvcj}
}
Kostenlos starten →