EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

RP-HPLC Method Development and Validation for the Simultaneous Estimation of Efonidipine and Telmisartan in Bulk and Dosage Forms

Syed Imam Pasha, Mohammad Maaz, Mohammed Adnan Sameer, Abdul Malik, M. Mushraff Ali Khan, Anupama Koneru

IJPAR JOURNAL · 13.07.2026 · 15 (3) · 1307-1315

DOI: 10.61096/ijpar.v15i3.1111 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IJPAR JOURNAL, online erschienen am 13.07.2026. Verfasst von Syed Imam Pasha und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A simple, precise, and reliable reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous determination of Telmisartan and Efonidipine in pharmaceutical dosage forms. Chromatographic conditions were optimized through multiple trials using different columns and mobile phase compositions. Optimal separation was achieved on a Platisil C18 column (250 × 4.6 mm, 5 µm) using a mobile phase consisting of methanol and phosphate buffer (60:40, v/v) adjusted to pH 6.0. The flow rate was maintained at 1.0 mL/min, and detection was carried out using a UV detector at 227 nm. Under these conditions, the retention times of Telmisartan and Efonidipine were found to be 2.25 min and 3.03 min, respectively. The method satisfied system suitability parameters, with resolution greater than 2, tailing factor less than 2, and theoretical plate count exceeding 2000.The method demonstrated excellent linearity over the concentration range of 10–200 µg/mL, with correlation coefficients (r²) of 0.9996 for Telmisartan and 0.9994 for Efonidipine. Accuracy was evaluated by recovery studies, yielding results in the range of 99.3% to 99.6%. Precision was confirmed through repeatability studies, with relative standard deviation (%RSD) values less than 1.5%, indicating good reproducibility. The limits of detection (LOD) and limits of quantification (LOQ) were found to be 1.20 µg/mL and 4.32 µg/mL for Telmisartan, and 0.96 µg/mL and 3.30 µg/mL for Efonidipine, respectively. Robustness and ruggedness studies demonstrated that the method remained unaffected by small, deliberate variations in analytical conditions, confirming its reliability. Overall, the validated RP-HPLC method is suitable for routine quality control analysis of Telmisartan and Efonidipine in combined pharmaceutical dosage forms.

Zitieren

APA

Pasha, S. I., Maaz, M., Sameer, M. A., Malik, A., Khan, M. M. A., & Koneru, A. (2026). RP-HPLC Method Development and Validation for the Simultaneous Estimation of Efonidipine and Telmisartan in Bulk and Dosage Forms. IJPAR JOURNAL, 15(3), 1307-1315. https://doi.org/10.61096/ijpar.v15i3.1111

Vancouver

Pasha SI, Maaz M, Sameer MA, Malik A, Khan MMA, Koneru A. RP-HPLC Method Development and Validation for the Simultaneous Estimation of Efonidipine and Telmisartan in Bulk and Dosage Forms. IJPAR JOURNAL. 2026;15(3):1307-1315. doi:10.61096/ijpar.v15i3.1111

BibTeX
@article{Pasha2026,
  author = {Pasha, Syed Imam and Maaz, Mohammad and Sameer, Mohammed Adnan and Malik, Abdul and Khan, M. Mushraff Ali and Koneru, Anupama},
  title = {RP-HPLC Method Development and Validation for the Simultaneous Estimation of Efonidipine and Telmisartan in Bulk and Dosage Forms},
  journal = {IJPAR JOURNAL},
  year = {2026},
  volume = {15},
  number = {3},
  pages = {1307--1315},
  doi = {10.61096/ijpar.v15i3.1111}
}
Kostenlos starten →