EUVIMEDEUVIMED entdecken
Crossref

Technical errors in pedicle screw placement in computer assisted minimally invasive spine surgery

Roberto Doria-Medina

FreiDok plus (Universitätsbibliothek Freiburg) · 01.01.2024

DOI: 10.6094/unifr/246318 ↗

Kurz gefasst

Fachartikel in der Zeitschrift FreiDok plus (Universitätsbibliothek Freiburg), erschienen am 01.01.2024. Verfasst von Roberto Doria-Medina.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The placement of pedicle screws (PS) has become a cornerstone in spinal surgery and computer assisted navigation (CAN) reduces PS misplacements. Most previous attempts on evaluating the technical accuracy by measuring deviations from the virtual and the real PS screws have been based on a preoperative computer tomography (CT) scan, both in fluoroscopy guided and in robotic navigation guided. As such, these studies did not address the fundamental question of the technical accuracy of the navigation device itself after intraoperative placement of the virtual PS or of intraoperative risk factors. Other studies that assessed the technical accuracy from intraoperative placed virtual screws were instead limited in size, generalizability, and without an analysis of possible risk factors. Therefore, we aim to investigate the technical errors of intraoperative CAN in the placement of PS in MISS and explore the associated risk factors for PS mispositioning.

Methods

In this retrospective study, 175 patients ≥18 years old (operated 2015-2021) with PS fixation were included. Intraoperative 3D scans were fused with the first postoperative CT scan. Primary endpoint was measured as angular deviation (PAD) in degrees and lateral deviation (APD) in mm between the planned and actual PS position and was defined as the technical errors. Established deviation criteria (according to Gertzbein) were correlated. Age, gender, body mass index (BMI), back tissue depth (BTD), PS loosening, surgical time (ST), estimated blood loss (EBL), PS size and type of navigation device were considered as possible outcome affecting variables. Statistical analyses were performed using Mann-Whitney and Kruskal-Wallis tests. A multivariate generalized linear model (GLM) analyzed the impact on the primary endpoint.

Results

952 PS were measured. The mean PAD was 5.32±3.70° and the mean APD was 2.97±1.83 mm. A larger PAD was associated with the use of the Spine Tracker compared to SpineMask®. More EBL and higher BMI were associated with greater APD. A larger PAD and APD were associated with longer ST. Higher PAD and APD were associated with PS loosening. PS length and male patients predicted better PAD, Spine Tracker predicted worse PAD, and longer ST predicted worse PAD and APD.

Conclusion

The technical error was 5.32° (PAD) and 2.97 mm (APD). PS dimensions, ST, EBL, BMI, navigation type, and gender category were associated with more PS deviations. Nevertheless, both clamp and adhesive fixed reference frames can be considered clinically accurate, but surgeons should be mindful of possible risk factors for technical inaccuracies. We encourage further studies to assess possible outcome affecting variables on PS placements.

Schlagwörter

pedicle screw placementcomputer-assisted navigationminimally invasive spine surgerytechnical accuracyangular deviationlateral deviationestimated blood lossbody mass indexoperative timepedicle screw loosening

Zitieren

APA

Doria-Medina, R. (2024). Technical errors in pedicle screw placement in computer assisted minimally invasive spine surgery. FreiDok plus (Universitätsbibliothek Freiburg). https://doi.org/10.6094/unifr/246318

Vancouver

Doria-Medina R. Technical errors in pedicle screw placement in computer assisted minimally invasive spine surgery. FreiDok plus (Universitätsbibliothek Freiburg). 2024. doi:10.6094/unifr/246318

BibTeX
@article{DoriaMedina2024,
  author = {Doria-Medina, Roberto},
  title = {Technical errors in pedicle screw placement in computer assisted minimally invasive spine surgery},
  journal = {FreiDok plus (Universitätsbibliothek Freiburg)},
  year = {2024},
  doi = {10.6094/unifr/246318}
}
Kostenlos starten →