Sonographic Assessment of Optic Nerve Sheath Diameter among Apparently Healthy Paediatrics in Kano Metropolis, Nigeria
Afrischolar Discovery · 09.07.2026
DOI: 10.60787/8h0p-9650 ↗Kurz gefasst
Fachartikel in der Zeitschrift Afrischolar Discovery, erschienen am 09.07.2026. Verfasst von Mohammed Sidi und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Ultrasound has been extensively used in the diagnosis and management of ophthalmic diseases. Reference values for normal optic nerve sheath diameter (ONSD) of healthy Paediatric individuals in a population is critical in the detection of raised intra-intracranial pressure (ICP) and other eye pathologies.
Aim
This study was aimed at evaluating the ONSD of healthy Paediatrics in Kano metropolis, Nigeria.
Methods
The design of the study was prospective and cross-sectional, with duration spanning February 2022 to February 2023. Convenience sampling technique was used to enlist 420 paediatric subjects. A portable digital ultrasound machine (Nortek CS 3), with 7.5 MHz linear transducer was used as instrument for data collection. The measurement of the ONSD was made at 3 mm posterior to the globe of the eye. Data was analysed using SPSS version 25.0. With level of significance set at ρ< 0.05.
Results
The ranges of the right and left ONSD for male subjects were 1.9 mm to 4.5 mm and 2.0 mm to 4.6 mm, and for the female subjects was 1.8mm to 4.4 mm and 1.8 mm to 4.5 mm respectively. A statistical significant difference in ONSD between Paediatric age groups was observed (ρ = 0.001). Correlation of ONSD with anthropometric variables was moderate in BMI (r = 0.361 – 0.541) and BSA (r = 0.301 - 0.584) and graduated from moderate to strong in age, height and weight (r = 0.404 – 0.788).
Conclusion
Normal reference values for the Paediatrics ONSD have been established. A statistically significant difference in ONSD between paediatric age groups was observed. The ONSD had a moderate to strong positive correlation with the anthropometrics variables.
Schlagwörter
Zitieren
APA
Sidi, M., Mahmud, S. A., Mansur, U., Ya’u, A., & Abubakar, A. A. (2026). Sonographic Assessment of Optic Nerve Sheath Diameter among Apparently Healthy Paediatrics in Kano Metropolis, Nigeria. Afrischolar Discovery. https://doi.org/10.60787/8h0p-9650
Vancouver
Sidi M, Mahmud SA, Mansur U, Ya’u A, Abubakar AA. Sonographic Assessment of Optic Nerve Sheath Diameter among Apparently Healthy Paediatrics in Kano Metropolis, Nigeria. Afrischolar Discovery. 2026. doi:10.60787/8h0p-9650
BibTeX
@article{Sidi2026,
author = {Sidi, Mohammed and Mahmud, Sha’awa Abdullahi and Mansur, Umar and Ya’u, Anas and Abubakar, Abubakar Aminu},
title = {Sonographic Assessment of Optic Nerve Sheath Diameter among Apparently Healthy Paediatrics in Kano Metropolis, Nigeria},
journal = {Afrischolar Discovery},
year = {2026},
doi = {10.60787/8h0p-9650}
}
EUVIMED