EUVIMEDEUVIMED entdecken
Crossref

Heart rate and oxygen saturation of vastus lateralis and gastrocnemius medialis muscles at maximal exercise intensity: a comparison between treadmill, elliptical trainer and cycle ergometry

Catarina Abrantes, Isabel Machado, Daniel Santarém

Motricidade · 2024 · 20 (S1)

DOI: 10.6063/motricidade.32139 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Motricidade, 2024. Verfasst von Catarina Abrantes und 2 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Maximal exercise intensity is widely used to assess physiological responses in various populations. The determination of muscle oxygen saturation (SmO2), using the emerging easy-to-use technique of near-infrared spectroscopy (NIRS), combined with the heart rate (HR) in response to different exercise modes (or ergometers), remains unclear. The aim was to compare the changes in SmO2 in the gastrocnemius medialis (GM) and vastus lateralis (VL) muscles, as well as the HR response at maximal exercise intensity performed on a treadmill, an elliptical trainer and a cycle ergometer. Fourteen healthy volunteers (age = 34.9 ± 9.1 years; height = 169.4 ± 8.6 cm; weight = 69.7 ± 9.8 kg) performed three incremental tests to maximal intensity on a treadmill, an elliptical trainer, and a cycle ergometer on different days (interspersed by at least 72 hours) in a random order. During the incremental tests, the HR (Garmin HRM3-SS, Kansas, USA) and the SmO2 (Moxy 3, Fortiori Design LLC, Hutchinson, USA) of VL and GM muscles were collected. The data of the last intensity level with one minute duration was used to determine average HR (HRavg), peak HR (HRpeak), average SmO2 (SmO2avg) and minimum SmO2 (SmO2min) in VL and GM muscles. Repeated measures ANOVA revealed an exercise mode effect on HRavg (F2,26=12.44, p=0.001, η2=0.150) and HRpeak (F2,26=13.15, p=0.001, η2=0.170). Higher values were found on HRavg on treadmill vs. cycle (177.2±7.5 vs. 167.5±13.4 bpm, p=0.005) and on elliptical (175.0±9.3 bpm, p=0.018) vs. cycle. A similar pattern was found on HRpeak with higher values on treadmill vs. cycle (183.9±2.1 vs. 172.9±3.7 bpm, p=0.004) and elliptical (180.5±2.5 bpm, p=0.017) vs. cycle. An exercise mode effect of SmO2min in VL (F2,20=5.24, p=0.015, η2=0.230) showed lower values on elliptical vs. cycle (15.0±10.7 vs. 37.6±18.2%, p=0.035). An exercise mode effect was also found in GM on SmO2avg (F2,24=27.19, p

Schlagwörter

Exercise modeCardiovascular exerciseAcute responseNear-infrared spectroscopy

Zitieren

APA

Abrantes, C., Machado, I., & Santarém, D. (2024). Heart rate and oxygen saturation of vastus lateralis and gastrocnemius medialis muscles at maximal exercise intensity: a comparison between treadmill, elliptical trainer and cycle ergometry. Motricidade, 20(S1). https://doi.org/10.6063/motricidade.32139

Vancouver

Abrantes C, Machado I, Santarém D. Heart rate and oxygen saturation of vastus lateralis and gastrocnemius medialis muscles at maximal exercise intensity: a comparison between treadmill, elliptical trainer and cycle ergometry. Motricidade. 2024;20(S1). doi:10.6063/motricidade.32139

BibTeX
@article{Abrantes2024,
  author = {Abrantes, Catarina and Machado, Isabel and Santarém, Daniel},
  title = {Heart rate and oxygen saturation of vastus lateralis and gastrocnemius medialis muscles at maximal exercise intensity: a comparison between treadmill, elliptical trainer and cycle ergometry},
  journal = {Motricidade},
  year = {2024},
  volume = {20},
  number = {S1},
  doi = {10.6063/motricidade.32139}
}
Kostenlos starten →