CBCT evaluation of two endodontic instrument retrieval systems: An in vitro study
Bioinformation · 31.10.2026 · 22 (10) · 6287-6293
DOI: 10.6026/973206300226287 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformation, online erschienen am 31.10.2026. Verfasst von Lavisha Arora.
Abstract (Originalsprache)
The removal of fractured NiTi instruments from root canals poses a major challenge in endodontics due to the risk of excessive dentin loss and root perforation. Therefore, it is of interest to compare the Masserann kit and C-FR2 retrieval system using CBCT and digital stopwatch timing in 60 extracted mandibular premolars. While both systems showed similar removal times, the Masserann kit preserved significantly more root dentin structure. Thus, the C-FR2 system exhibited a significantly lower perforation rate, offering a safer clinical option despite causing greater dentin loss.
Zitieren
APA
Arora, L. (2026). CBCT evaluation of two endodontic instrument retrieval systems: An in vitro study. Bioinformation, 22(10), 6287-6293. https://doi.org/10.6026/973206300226287
Vancouver
Arora L. CBCT evaluation of two endodontic instrument retrieval systems: An in vitro study. Bioinformation. 2026;22(10):6287-6293. doi:10.6026/973206300226287