Fachartikel in der Zeitschrift Bioinformation, online erschienen am 30.06.2026. Verfasst von Ravi Ranjan Sinha und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics Crown and Bridge, The Oxford Dental College, Rajiv Gandhi University of Health Sciences, Bengaluru, Karnataka, India. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Achieving rapid and stable osseointegration remains a persistent challenge in dental implantology, particularly with variations in implant surface properties. Therefore, it is of interest to compare the effects of hydrophilic and hydrophobic implant surface coatings on osseointegration using clinical and radiographic parameters. Hence, a prospective comparative design involving 100 patients showed that hydrophilic implants yielded significantly higher implant stability (ISQ values) and reduced peri-implant bone loss over a 6-month follow-up period. Improved peri-implant soft tissue health, evidenced by reduced probing depth and bleeding on probing, was also observed in the hydrophilic group. Thus, we report hydrophilic surface modification as a superior strategy for enhancing early osseointegration and improving overall implant prognosis.

Schlagwörter

Stichwörter der Autor:innen

Osseointegrationdental implantshydrophilic implant surfacehydrophobic implant surfaceimplant stability

Autor:innen und Institutionen

  • Department of Prosthodontics Crown and Bridge, The Oxford Dental College, Rajiv Gandhi University of Health Sciences, Bengaluru, Karnataka, India.
  • Department of Dental Surgery, Sikkim Manipal Institute of Medical Sciences, Sikkim Manipal University, Gangtok, Sikkim, India.
  • Department of Conservative Dentistry and Endodontics, RKDF Dental College and Research Centre, RKDF University, Bhopal, Madhya Pradesh, India.
  • Department of Orthodontics, Mishra Dental Clinic and Orthodontic Care, Bhubaneswar, Odisha, India.
  • Department of Prosthodontics and Implantology, SB Patil Institute of Dental Science and Research, Rajiv Gandhi University of Health Sciences, Bidar, Karnataka, India.

Zitieren

APA

Sinha, R. R., Kashyap, S., Sahu, G. K., Chauhan, G. K., Mishra, P., & Mayadevi, M. (2026). Hydrophilic versus hydrophobic implant coatings: A comparative osseointegration study. Bioinformation, 22(06), 3289-3293. https://doi.org/10.6026/973206300223289

Vancouver

Sinha RR, Kashyap S, Sahu GK, Chauhan GK, Mishra P, Mayadevi M. Hydrophilic versus hydrophobic implant coatings: A comparative osseointegration study. Bioinformation. 2026;22(06):3289-3293. doi:10.6026/973206300223289

BibTeX
@article{Sinha2026,
  author = {Sinha, Ravi Ranjan and Kashyap, Sandeep and Sahu, Gourav Kumar and Chauhan, Gurdeep Kaur and Mishra, Pragati and Mayadevi, Mayadevi},
  title = {Hydrophilic versus hydrophobic implant coatings: A comparative osseointegration study},
  journal = {Bioinformation},
  year = {2026},
  volume = {22},
  number = {06},
  pages = {3289--3293},
  doi = {10.6026/973206300223289}
}
Kostenlos starten →