In vitro assessment for primary stability of self-drilling orthodontic mini-implants: Pull-out testing at different insertion angles
Bioinformation · 31.05.2026 · 22 (5) · 2792-2798
DOI: 10.6026/973206300222792 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformation, online erschienen am 31.05.2026. Verfasst von Poulomi Roy und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics and dentofacial orthopaedics, Burdwan Dental College and Hospital, Burdwan, West Bengal, India. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Achieving optimal primary stability of orthodontic mini-implants remains a clinical challenge because the ideal insertion angle for self-drilling mini-implants has not been clearly established. Therefore, it is of interest to evaluate and compare the primary stability of self-drilling orthodontic mini-implants inserted into artificial bone blocks at four different angles (30°, 45°, 60° and 90°) using pull-out resistance testing. Eighty titanium alloy mini-implants (1.6 mm diameter, 8 mm length) were randomly allocated into four groups (n=20 each) and inserted into standardized synthetic bone blocks simulating D2 bone density with a custom angular guide, followed by pull-out testing in a universal testing machine at a crosshead speed of 1 mm/min. Mini-implants placed at 60° showed the highest mean pull-out force (324.67 ± 28.43 N), followed by 45° (298.52 ± 31.76 N), 90° (267.38 ± 25.91 N) and 30° (231.14 ± 33.82 N), with statistically significant differences between the groups. Thus, insertion at 60° to the bone surface provided the high primary stability. It may be considered the biomechanically most favorable angulation for self-drilling orthodontic mini-implants.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics and dentofacial orthopaedics, Burdwan Dental College and Hospital, Burdwan, West Bengal, India.
- Department of Dentistry, School of Dentistry, Central Asian University, Uzbekistan.
- Department of Orthodontics and Dentofacial Orthopaedics, NIMS Dental College & Hospital, NIMS University, Rajasthan, Jaipur, India.
- Department of Orthodontics and Dentofacial Orthopaedics, Geetanjali Dental College, Udaipur, India.
- Department of Orthodontics and Dentofacial Orthopedics, Goenka Research Institute of Dental Science, Pethapur, Gandhinagar, Gujarat, India.
Zitieren
APA
Roy, P., Chawla, R., Kumar, A., Pandya, H., Rastogi Gupta, S., & Shah, K. (2026). In vitro assessment for primary stability of self-drilling orthodontic mini-implants: Pull-out testing at different insertion angles. Bioinformation, 22(5), 2792-2798. https://doi.org/10.6026/973206300222792
Vancouver
Roy P, Chawla R, Kumar A, Pandya H, Rastogi Gupta S, Shah K. In vitro assessment for primary stability of self-drilling orthodontic mini-implants: Pull-out testing at different insertion angles. Bioinformation. 2026;22(5):2792-2798. doi:10.6026/973206300222792
BibTeX
@article{Roy2026,
author = {Roy, Poulomi and Chawla, Riddhi and Kumar, Ashish and Pandya, Harshit and Rastogi Gupta, Shikha and Shah, Kashyap},
title = {In vitro assessment for primary stability of self-drilling orthodontic mini-implants: Pull-out testing at different insertion angles},
journal = {Bioinformation},
year = {2026},
volume = {22},
number = {5},
pages = {2792--2798},
doi = {10.6026/973206300222792}
}
EUVIMED