EUVIMEDEUVIMED entdecken
Open Access

In vitro assessment for primary stability of self-drilling orthodontic mini-implants: Pull-out testing at different insertion angles

Poulomi Roy, Riddhi Chawla, Ashish Kumar, Harshit Pandya, Shikha Rastogi Gupta, Kashyap Shah

Bioinformation · 31.05.2026 · 22 (5) · 2792-2798

DOI: 10.6026/973206300222792 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioinformation, online erschienen am 31.05.2026. Verfasst von Poulomi Roy und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics and dentofacial orthopaedics, Burdwan Dental College and Hospital, Burdwan, West Bengal, India. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Achieving optimal primary stability of orthodontic mini-implants remains a clinical challenge because the ideal insertion angle for self-drilling mini-implants has not been clearly established. Therefore, it is of interest to evaluate and compare the primary stability of self-drilling orthodontic mini-implants inserted into artificial bone blocks at four different angles (30°, 45°, 60° and 90°) using pull-out resistance testing. Eighty titanium alloy mini-implants (1.6 mm diameter, 8 mm length) were randomly allocated into four groups (n=20 each) and inserted into standardized synthetic bone blocks simulating D2 bone density with a custom angular guide, followed by pull-out testing in a universal testing machine at a crosshead speed of 1 mm/min. Mini-implants placed at 60° showed the highest mean pull-out force (324.67 ± 28.43 N), followed by 45° (298.52 ± 31.76 N), 90° (267.38 ± 25.91 N) and 30° (231.14 ± 33.82 N), with statistically significant differences between the groups. Thus, insertion at 60° to the bone surface provided the high primary stability. It may be considered the biomechanically most favorable angulation for self-drilling orthodontic mini-implants.

Schlagwörter

Stichwörter der Autor:innen

Orthodontic mini-implantinsertion angleprimary stabilitypull-out testtemporary anchorage device (TAD)

Autor:innen und Institutionen

  • Department of Orthodontics and dentofacial orthopaedics, Burdwan Dental College and Hospital, Burdwan, West Bengal, India.
  • Department of Dentistry, School of Dentistry, Central Asian University, Uzbekistan.
  • Department of Orthodontics and Dentofacial Orthopaedics, NIMS Dental College & Hospital, NIMS University, Rajasthan, Jaipur, India.
  • Department of Orthodontics and Dentofacial Orthopaedics, Geetanjali Dental College, Udaipur, India.
  • Department of Orthodontics and Dentofacial Orthopedics, Goenka Research Institute of Dental Science, Pethapur, Gandhinagar, Gujarat, India.

Zitieren

APA

Roy, P., Chawla, R., Kumar, A., Pandya, H., Rastogi Gupta, S., & Shah, K. (2026). In vitro assessment for primary stability of self-drilling orthodontic mini-implants: Pull-out testing at different insertion angles. Bioinformation, 22(5), 2792-2798. https://doi.org/10.6026/973206300222792

Vancouver

Roy P, Chawla R, Kumar A, Pandya H, Rastogi Gupta S, Shah K. In vitro assessment for primary stability of self-drilling orthodontic mini-implants: Pull-out testing at different insertion angles. Bioinformation. 2026;22(5):2792-2798. doi:10.6026/973206300222792

BibTeX
@article{Roy2026,
  author = {Roy, Poulomi and Chawla, Riddhi and Kumar, Ashish and Pandya, Harshit and Rastogi Gupta, Shikha and Shah, Kashyap},
  title = {In vitro assessment for primary stability of self-drilling orthodontic mini-implants: Pull-out testing at different insertion angles},
  journal = {Bioinformation},
  year = {2026},
  volume = {22},
  number = {5},
  pages = {2792--2798},
  doi = {10.6026/973206300222792}
}
Kostenlos starten →