EUVIMEDEUVIMED entdecken
Open Access

Comparative evaluation of titanium miniplates versus 3D plates in mandibular fracture fixation: A clinical study

M L V Surya Mithra, Sandhya Joshi, Chaitanya Varangaonkar, Divija Jasti, Chiluveru Manoj Kumar, Lahari Priya Singareddy, Rahul Tiwari

Bioinformation · 30.04.2026 · 22 (4) · 2435-2438

DOI: 10.6026/973206300222435 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioinformation, 2026-04. Verfasst von M L V Surya Mithra und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, Mamata Institute of Dental Sciences, Bachupally, Hyderabad, Telangana, India. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Inadequate fixation stability in mandibular fracture management often leads to postoperative complications and delayed functional recovery. Therefore, it is of interest to compare titanium miniplates and three-dimensional plates for mandibular fracture fixation in sixty randomized patients. Postoperative stability, infection, occlusion, pain and mouth opening were assessed over a twelve-week follow-up. 3D plate's showed superior stability with reduced operative time and lower complication rates. Thus, we show 3D plating systems provide more reliable fixation and faster functional rehabilitation than conventional miniplates.

Schlagwörter

Stichwörter der Autor:innen

Mandibular fracturesmaxillofacial traumaosteosynthesisthree-dimensional platestitanium miniplates

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Surgery, Mamata Institute of Dental Sciences, Bachupally, Hyderabad, Telangana, India.
  • Department of Oral and Maxillofacial Surgery, National Academy of Medical Sciences, Bir Hospital, National Trauma Center, Kathmandu, Bagmati, Nepal.
  • Department of Oral and Maxillofacial Surgery, Shiyas and Ifthikar Medical Centre, Sharjah, United Arab Emirates.
  • Department of Dental Surgery, Mamata Dental College and Hospital, Khammam, Telangana, India.
  • Department of Oral and Maxillofacial Surgery, Sri Sai College of Dental Surgery, Vikarabad, Telangana, India.
  • Department of Public Health, St. Francis College, New York City, New York, USA.

Zitieren

APA

Mithra, M. L. V. S., Joshi, S., Varangaonkar, C., Jasti, D., Manoj Kumar, C., Singareddy, L. P., & Tiwari, R. (2026). Comparative evaluation of titanium miniplates versus 3D plates in mandibular fracture fixation: A clinical study. Bioinformation, 22(4), 2435-2438. https://doi.org/10.6026/973206300222435

Vancouver

Mithra MLVS, Joshi S, Varangaonkar C, Jasti D, Manoj Kumar C, Singareddy LP, et al. Comparative evaluation of titanium miniplates versus 3D plates in mandibular fracture fixation: A clinical study. Bioinformation. 2026;22(4):2435-2438. doi:10.6026/973206300222435

BibTeX
@article{Mithra2026,
  author = {Mithra, M L V Surya and Joshi, Sandhya and Varangaonkar, Chaitanya and Jasti, Divija and Manoj Kumar, Chiluveru and Singareddy, Lahari Priya and Tiwari, Rahul},
  title = {Comparative evaluation of titanium miniplates versus 3D plates in mandibular fracture fixation: A clinical study},
  journal = {Bioinformation},
  year = {2026},
  volume = {22},
  number = {4},
  pages = {2435--2438},
  doi = {10.6026/973206300222435}
}
Kostenlos starten →