Ultrasound versus traditional formula for subglottic diameter-based uncuffed endotracheal tube selection in pediatric patients
Bioinformation · 30.04.2026 · 22 (4) · 2338-2341
DOI: 10.6026/973206300222338 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformation, online erschienen am 30.04.2026. Verfasst von Urmila Keshari und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology, Gandhi medical College, Bhopal, India. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Accurate endotracheal tube (ETT) size selection is vital in pediatric anesthesia, yet traditional age-based formulas such as the modified Cole's formula are often unreliable; ultrasonography (USG), by directly visualizing the subglottic airway, offers a more precise alternative. In a cross-sectional study of 75 children aged 1-8 years, elective cases underwent ultrasound measurement of the mean transverse subglottic diameter, while emergency cases relied on the age-based formula. Ultrasound demonstrated superior accuracy, reducing ETT changes (5% vs. 20%), second intubation attempts (5% vs. 20%) and post-intubation complications (4.5% vs. 16.5%). It also showed higher sensitivity (100% vs. 96%) for predicting appropriate tube size. Thus, we show ultrasonography as a more reliable method than traditional formulas and recommend its integration into routine pediatric airway assessment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anaesthesiology, Gandhi medical College, Bhopal, India.
- Department of Radiology, Gandhi medical College, Bhopal, India.
- Consultant anaesthesiologist, Aster Prime Hospital, Hyderabad, India.
Zitieren
APA
Keshari, U., Thakur, R., Soni, S., R P, K., Kaushal, L., & Yadav, A. K. (2026). Ultrasound versus traditional formula for subglottic diameter-based uncuffed endotracheal tube selection in pediatric patients. Bioinformation, 22(4), 2338-2341. https://doi.org/10.6026/973206300222338
Vancouver
Keshari U, Thakur R, Soni S, R P K, Kaushal L, Yadav AK. Ultrasound versus traditional formula for subglottic diameter-based uncuffed endotracheal tube selection in pediatric patients. Bioinformation. 2026;22(4):2338-2341. doi:10.6026/973206300222338
BibTeX
@article{Keshari2026,
author = {Keshari, Urmila and Thakur, Rajni and Soni, Sherin and R P, Kaushal and Kaushal, Lovely and Yadav, Ajay Kumar},
title = {Ultrasound versus traditional formula for subglottic diameter-based uncuffed endotracheal tube selection in pediatric patients},
journal = {Bioinformation},
year = {2026},
volume = {22},
number = {4},
pages = {2338--2341},
doi = {10.6026/973206300222338}
}