3D predictability assessment of clear aligners versus fixed appliances using CBCT
Bioinformation · 30.04.2026 · 22 (4) · 2219-2223
DOI: 10.6026/973206300222219 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformation, online erschienen am 30.04.2026. Verfasst von Subash Chandra Nayak und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics and Dentofacial Orthopaedics, Hi-Tech Dental College and Hospital, Bhubaneshwar, Odisha, India. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Predictability of orthodontic tooth movement varies between clear aligners and fixed appliances, yet three-dimensional comparative evidence remains limited for complex cases. This prospective study randomized 60 complex orthodontic patients to clear aligners (n=30) or fixed appliances (n=30), using baseline/planned/post-treatment CBCT superimposition to quantify accuracy across three planes of space. Clear aligners excelled in incisor torque (87.3% versus 82.2%, p=0.001) and anterior intrusion (91.2% versus 82.8%, p=0.002), while fixed appliances were superior for canine/premolar rotation (88.9% versus 78.6%, p=0.001) and anterior extrusion (85.7% versus 76.2%, p=0.004). Overall treatment predictability was comparable (clear aligners 84.6ą7.8% versus fixed 82.3ą8.9%, p=0.286), revealing modality-specific strengths for targeted movements. This data help in orthodontic planning by establishing CBCT-based evidence for modality selection based on movement type, enhancing precision in complex cases.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics and Dentofacial Orthopaedics, Hi-Tech Dental College and Hospital, Bhubaneshwar, Odisha, India.
- Department of Orthodontics and Dentofacial Orthopaedics, St. Joseph Dental College & Hospital, Duggirala, Eluru, Andhra Pradesh, India.
- Private Practitioner, Dental Surgeon, SRK Dental Clinic, Hyderabad, Telangana, India.
- Department of Periodontology and Implantology, MNR Dental College and Hospital, Sangareddy, Hyderabad, Telangana, India.
Zitieren
APA
Nayak, S. C., Bommasani, M. B., N V, U. S. M., V V, C. T., S J, S., Varma Rudraraju, V. S., Naaz, R., & Ahmed, M. K. (2026). 3D predictability assessment of clear aligners versus fixed appliances using CBCT. Bioinformation, 22(4), 2219-2223. https://doi.org/10.6026/973206300222219
Vancouver
Nayak SC, Bommasani MB, N V USM, V V CT, S J S, Varma Rudraraju VS, et al. 3D predictability assessment of clear aligners versus fixed appliances using CBCT. Bioinformation. 2026;22(4):2219-2223. doi:10.6026/973206300222219
BibTeX
@article{Nayak2026,
author = {Nayak, Subash Chandra and Bommasani, Madhu Bhaskar and N V, Uday Sagar Maddula and V V, Charan Teja and S J, Siddardha and Varma Rudraraju, Vijay Srikrishna and Naaz, Rubeena and Ahmed, Md Kafeel},
title = {3D predictability assessment of clear aligners versus fixed appliances using CBCT},
journal = {Bioinformation},
year = {2026},
volume = {22},
number = {4},
pages = {2219--2223},
doi = {10.6026/973206300222219}
}
EUVIMED