Bispectral index-guided versus standard anaesthesia monitoring for intraoperative awareness prevention
Bioinformation · 28.02.2026 · 22 (2) · 931-934
DOI: 10.6026/973206300220931 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformation, online erschienen am 28.02.2026. Verfasst von Brajesh Kumar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Consultant Anaesthesiologist, Bansal Hospital, Sagar, Madhya Pradesh, India. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Although bispectral index (BIS) monitoring provides an objective measure of hypnotic depth, its routine use to prevent awareness remains debated due to conflicting evidence and cost considerations. Therefore, it is of interest to evaluate BIS-guided versus clinically guided sevoflurane anaesthesia in 200 adults undergoing elective surgery over 60 minutes. No definite intraoperative awareness occurred in either group, confirmed by modified Brice interviews up to 30 days postoperatively. BIS monitoring reduced sevoflurane consumption by 24% (1.7 ± 0.4 vs 2.2 ± 0.5 MAC-hours; p < 0.001) and accelerated extubation (7.9 ± 2.3 vs 10.8 ± 3.1 min; p < 0.001) and PACU discharge (46.2 ± 11.8 vs 56.9 ± 14.7 min; p < 0.001). It also provided greater haemodynamic stability, with lower MAP variability (11.4 ± 3.9% vs 16.8 ± 5.6%; p < 0.001). BIS monitoring optimizes anaesthetic delivery and recovery efficiency without lowering awareness incidence compared to vigilant clinical monitoring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Consultant Anaesthesiologist, Bansal Hospital, Sagar, Madhya Pradesh, India.
- Department of Anaesthesiology, Gajra Raja Medical college Gwalior, Madhya Pradesh, India.
Zitieren
APA
Kumar, B., Ekka, N., Chauhan, A. S., & Shrivastava, S. (2026). Bispectral index-guided versus standard anaesthesia monitoring for intraoperative awareness prevention. Bioinformation, 22(2), 931-934. https://doi.org/10.6026/973206300220931
Vancouver
Kumar B, Ekka N, Chauhan AS, Shrivastava S. Bispectral index-guided versus standard anaesthesia monitoring for intraoperative awareness prevention. Bioinformation. 2026;22(2):931-934. doi:10.6026/973206300220931
BibTeX
@article{Kumar2026,
author = {Kumar, Brajesh and Ekka, Nancy and Chauhan, Aditya Singh and Shrivastava, Sourabh},
title = {Bispectral index-guided versus standard anaesthesia monitoring for intraoperative awareness prevention},
journal = {Bioinformation},
year = {2026},
volume = {22},
number = {2},
pages = {931--934},
doi = {10.6026/973206300220931}
}
EUVIMED