EUVIMEDEUVIMED entdecken
Open Access

Bispectral index-guided versus standard anaesthesia monitoring for intraoperative awareness prevention

Brajesh Kumar, Nancy Ekka, Aditya Singh Chauhan, Sourabh Shrivastava

Bioinformation · 28.02.2026 · 22 (2) · 931-934

DOI: 10.6026/973206300220931 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioinformation, online erschienen am 28.02.2026. Verfasst von Brajesh Kumar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Consultant Anaesthesiologist, Bansal Hospital, Sagar, Madhya Pradesh, India. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Although bispectral index (BIS) monitoring provides an objective measure of hypnotic depth, its routine use to prevent awareness remains debated due to conflicting evidence and cost considerations. Therefore, it is of interest to evaluate BIS-guided versus clinically guided sevoflurane anaesthesia in 200 adults undergoing elective surgery over 60 minutes. No definite intraoperative awareness occurred in either group, confirmed by modified Brice interviews up to 30 days postoperatively. BIS monitoring reduced sevoflurane consumption by 24% (1.7 ± 0.4 vs 2.2 ± 0.5 MAC-hours; p < 0.001) and accelerated extubation (7.9 ± 2.3 vs 10.8 ± 3.1 min; p < 0.001) and PACU discharge (46.2 ± 11.8 vs 56.9 ± 14.7 min; p < 0.001). It also provided greater haemodynamic stability, with lower MAP variability (11.4 ± 3.9% vs 16.8 ± 5.6%; p < 0.001). BIS monitoring optimizes anaesthetic delivery and recovery efficiency without lowering awareness incidence compared to vigilant clinical monitoring.

Schlagwörter

Stichwörter der Autor:innen

Bispectral index (BIS)depth of anaesthesia monitoringexplicit recallhaemodynamic stabilityintraoperative awarenessrecovery profilesevoflurane consumption

Autor:innen und Institutionen

  • Consultant Anaesthesiologist, Bansal Hospital, Sagar, Madhya Pradesh, India.
  • Department of Anaesthesiology, Gajra Raja Medical college Gwalior, Madhya Pradesh, India.

Zitieren

APA

Kumar, B., Ekka, N., Chauhan, A. S., & Shrivastava, S. (2026). Bispectral index-guided versus standard anaesthesia monitoring for intraoperative awareness prevention. Bioinformation, 22(2), 931-934. https://doi.org/10.6026/973206300220931

Vancouver

Kumar B, Ekka N, Chauhan AS, Shrivastava S. Bispectral index-guided versus standard anaesthesia monitoring for intraoperative awareness prevention. Bioinformation. 2026;22(2):931-934. doi:10.6026/973206300220931

BibTeX
@article{Kumar2026,
  author = {Kumar, Brajesh and Ekka, Nancy and Chauhan, Aditya Singh and Shrivastava, Sourabh},
  title = {Bispectral index-guided versus standard anaesthesia monitoring for intraoperative awareness prevention},
  journal = {Bioinformation},
  year = {2026},
  volume = {22},
  number = {2},
  pages = {931--934},
  doi = {10.6026/973206300220931}
}
Kostenlos starten →