EUVIMEDEUVIMED entdecken
Open Access

Evaluation of diagnostic accuracy using routine laboratory parameters

Trushna Shah, Anand Chauhan, Shyama Manojkumar Chag, Kirti Nishant Vyas

Bioinformation · 28.02.2026 · 22 (2) · 683-688

DOI: 10.6026/973206300220683 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioinformation, online erschienen am 28.02.2026. Verfasst von Trushna Shah und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biochemistry, Smt BK Shah Medical Institute and Research Center, Sumandeep Vidyapeeth Deemed to be University, Waghodia, Vadodara, Guja…. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early disease detection remains challenging in clinical practice, often leading to delayed diagnosis and poorer health outcomes. Therefore, it is of interest to evaluate the diagnostic accuracy of routine laboratory parameters for early disease detection among 486 adults attending a tertiary care hospital between January 2023 and December 2024. Standard laboratory investigations including complete blood count, metabolic panel, liver and kidney function tests and inflammatory markers were analyzed against confirmed diagnostic outcomes using sensitivity, specificity, predictive values and receiver operating characteristic analysis. Combined laboratory panels demonstrated significantly higher diagnostic accuracy (AUC = 0.847) than individual parameters, with inflammatory markers showing the highest sensitivity (82.4%) and the neutrophil-to-lymphocyte ratio providing the best sensitivity-specificity balance. Integration of multiple routine laboratory parameters may therefore offer a cost-effective and practical strategy for improving early disease detection in diverse healthcare settings.

Schlagwörter

Stichwörter der Autor:innen

Diagnostic accuracyearly detectionlaboratory parametersscreening, sensitivityspecificity

Autor:innen und Institutionen

  • Department of Biochemistry, Smt BK Shah Medical Institute and Research Center, Sumandeep Vidyapeeth Deemed to be University, Waghodia, Vadodara, Gujarat, India.
  • Department of Pathology, CU Shah Medical College, Surendranagar, Gujarat, India.
  • Department of Pathology, Pramukh Swami Medical College, Bhaikaka University, Karamsad, Gujarat, India.
  • Department of Pathology, Dr ND Desai Faculty of Medical Science and Research, Dharmsinh Desai University, Nadiad, Gujarat, India.

Zitieren

APA

Shah, T., Chauhan, A., Chag, S. M., & Vyas, K. N. (2026). Evaluation of diagnostic accuracy using routine laboratory parameters. Bioinformation, 22(2), 683-688. https://doi.org/10.6026/973206300220683

Vancouver

Shah T, Chauhan A, Chag SM, Vyas KN. Evaluation of diagnostic accuracy using routine laboratory parameters. Bioinformation. 2026;22(2):683-688. doi:10.6026/973206300220683

BibTeX
@article{Shah2026,
  author = {Shah, Trushna and Chauhan, Anand and Chag, Shyama Manojkumar and Vyas, Kirti Nishant},
  title = {Evaluation of diagnostic accuracy using routine laboratory parameters},
  journal = {Bioinformation},
  year = {2026},
  volume = {22},
  number = {2},
  pages = {683--688},
  doi = {10.6026/973206300220683}
}
Kostenlos starten →