Comparison between landmark and ultrasound-guided techniques for internal jugular vein cannulation: A prospective observational study

Rashmi Pal, Vijendra Singh Thakur, Rashpal Singh Gill, Harshita Dutta Prajapati

Bioinformation · 30.09.2025 · 21 (09) · 2946-2949

DOI: 10.6026/973206300212946 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioinformation, online erschienen am 30.09.2025. Verfasst von Rashmi Pal und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, MGM Medical College Indore, Madhya Pradesh, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Internal jugular vein cannulation still has complications especially with landmark (LM) technique where no imaging used. Therefore, it is of interest to compare ultrasound-guided (USG) and LM techniques in 70 patients. USG group showed better first-attempt success, shorter flash time, faster cannulation and less complication. Arterial puncture, hematoma, pneumothorax and catheter displacement were seen only in LM group proving USG safer and faster for central venous access.

Schlagwörter

Stichwörter der Autor:innen

Ultrasonographycatheterization central venousjugular veinsprospective studiestreatment outcome

Autor:innen und Institutionen

  • Department of Anesthesiology, MGM Medical College Indore, Madhya Pradesh, India.

Zitieren

APA

Pal, R., Thakur, V. S., Gill, R. S., & Prajapati, H. D. (2025). Comparison between landmark and ultrasound-guided techniques for internal jugular vein cannulation: A prospective observational study. Bioinformation, 21(09), 2946-2949. https://doi.org/10.6026/973206300212946

Vancouver

Pal R, Thakur VS, Gill RS, Prajapati HD. Comparison between landmark and ultrasound-guided techniques for internal jugular vein cannulation: A prospective observational study. Bioinformation. 2025;21(09):2946-2949. doi:10.6026/973206300212946

BibTeX
@article{Pal2025,
  author = {Pal, Rashmi and Thakur, Vijendra Singh and Gill, Rashpal Singh and Prajapati, Harshita Dutta},
  title = {Comparison between landmark and ultrasound-guided techniques for internal jugular vein cannulation: A prospective observational study},
  journal = {Bioinformation},
  year = {2025},
  volume = {21},
  number = {09},
  pages = {2946--2949},
  doi = {10.6026/973206300212946}
}
Kostenlos starten →