Impact of abutment angulation on the accuracy of closed tray versus open tray implant impressions using noble bio-care active implants
Bioinformation · 30.06.2025 · 21 (06) · 1370-1374
DOI: 10.6026/973206300211370 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformation, online erschienen am 30.06.2025. Verfasst von Shaik Riyaz Basha und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of, Malla Reddy Institute of Dental Sciences, Malla Reddy Vishwavidyapeeth, Hyderabad, Telangana, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
The influence of abutment angulation on implant impression accuracy by comparing Closed Tray and Open Tray techniques in a clinical setting is of interest to dentists. Hence, a prospective cross-sectional analysis was conducted on 60 patients receiving implant-supported prostheses, stratified by abutment angulation (0°C, 15°C and 30–45°C). Impressions were made using polyvinyl siloxane and accuracy was quantified via mean MM discrepancy and procedural performance scores. The Open Tray technique demonstrated superior dimensional fidelity (mean discrepancy = 0.46 mm) versus the Closed Tray (0.72 mm), with significantly higher rates of clinically acceptable impressions and procedural efficacy. Logistic regression identified procedural proficiency as a strong predictor of impression precision. These findings underscore the diagnostic superiority of the Open Tray technique, particularly in angulated scenarios, reinforcing its value in enhancing prosthetic accuracy and clinical predictability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of, Malla Reddy Institute of Dental Sciences, Malla Reddy Vishwavidyapeeth, Hyderabad, Telangana, India.
- Sri Venkata Sai Dental College, Mahbubnagar, Telangana, India.
- Department of Prosthodontics, Mamata Institute of Dental Sciences, Bachupally, Hyderabad, Telangana, India.
- Department of Prosthodontics, Malla reddy institute of dental sciences, Malla Reddy Vishwavidyapeeth, Hyderabad, Telangana, India.
- Department of Prosthodontics, Smilead Dental Care, Hyderabad, Telangana, India.
- Intern, Kalinga Institute of Dental Sciences, Kalinga Institute of Industrial Technology (KIIT), Deemed to be University, Patia, Bhubaneswar, Odisha, India.
Zitieren
APA
Basha, S. R., Dondla, S., Channamsetty, P., Satyavathi, B., Reddy, S. S., K, S., & Agarwal, A. (2025). Impact of abutment angulation on the accuracy of closed tray versus open tray implant impressions using noble bio-care active implants. Bioinformation, 21(06), 1370-1374. https://doi.org/10.6026/973206300211370
Vancouver
Basha SR, Dondla S, Channamsetty P, Satyavathi B, Reddy SS, K S, et al. Impact of abutment angulation on the accuracy of closed tray versus open tray implant impressions using noble bio-care active implants. Bioinformation. 2025;21(06):1370-1374. doi:10.6026/973206300211370
BibTeX
@article{Basha2025,
author = {Basha, Shaik Riyaz and Dondla, Shravani and Channamsetty, Praveena and Satyavathi, Badugu and Reddy, Satheesh Simha and K, Srivani and Agarwal, Amisha},
title = {Impact of abutment angulation on the accuracy of closed tray versus open tray implant impressions using noble bio-care active implants},
journal = {Bioinformation},
year = {2025},
volume = {21},
number = {06},
pages = {1370--1374},
doi = {10.6026/973206300211370}
}
EUVIMED