Investigation of the Usefulness of Monte Carlo Simulation in Electron Beam Therapy Using Body Surface Lead Cutout

Naohito Ono

Japanese Journal of Radiological Technology · 2024

DOI: 10.6009/jjrt.2024-1404 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2024. Verfasst von Naohito Ono. Beteiligte Einrichtung: Department of Radiology, Juntendo University Shizuoka Hospital. Hauptthemen laut MEDLINE: Electrons, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The purpose of this study was to understand the PDD and OAR during electron beam therapy using lead cutout on the body surface. METHODS: The Monte Carlo code PHITS version 3.24 was used to simulate PDD and OAR. The simulation results were compared with actual measurements using a silicon diode detector to evaluate the validity of the simulation results. RESULTS: The simulated PDD and OAR parameters of the linac agreed with the measured values within 2 mm. When the lead cutout on the body surface was used, all parameters except for R100 agreed with the measured values within 2 mm. The cutout sizes of the broad-beam square irradiation fields were 3 cm for 6 MeV, 5 cm for 12 MeV, and 8 cm for 18 MeV when the lead cutout on the body surface was used. CONCLUSION: The Monte Carlo simulation was useful for understanding the PDD and OAR of the lead cutout irradiation fields, which are difficult to measure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectronsRadiotherapy Planning, Computer-AssistedMonte Carlo MethodComputer SimulationParticle AcceleratorsRadiometryRadiotherapy Dosage

Stichwörter der Autor:innen

Monte Carlo simulationbody surface cutoutelectron beam therapyoff-axis ratio (OAR)percent depth dose (PDD)

Autor:innen und Institutionen

  • Department of Radiology, Juntendo University Shizuoka Hospital.

Zitieren

APA

Ono, N. (2024). Investigation of the Usefulness of Monte Carlo Simulation in Electron Beam Therapy Using Body Surface Lead Cutout. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.2024-1404

Vancouver

Ono N. Investigation of the Usefulness of Monte Carlo Simulation in Electron Beam Therapy Using Body Surface Lead Cutout. Japanese Journal of Radiological Technology. 2024. doi:10.6009/jjrt.2024-1404

BibTeX
@article{Ono2024,
  author = {Ono, Naohito},
  title = {Investigation of the Usefulness of Monte Carlo Simulation in Electron Beam Therapy Using Body Surface Lead Cutout},
  journal = {Japanese Journal of Radiological Technology},
  year = {2024},
  doi = {10.6009/jjrt.2024-1404}
}
Kostenlos starten →