Verification of Dose Distribution in Cervical Cancer Brachytherapy Using Metal and Plastic Applicators
Japanese Journal of Radiological Technology · 2023
DOI: 10.6009/jjrt.2023-1375 ↗Kurz gefasst
Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2023. Verfasst von Fumihiro Tomita und 10 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences. Hauptthemen laut MEDLINE: Uterine Cervical Neoplasms, Brachytherapy. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To validate the point-A dose and dose distribution of metal and resin applicators in comparison with those of TG-43U1. METHODS: The metal and resin applicators consisting of tandem and ovoid were modeled by the egs_brachy. The doses to point A and dose distributions considering each applicator were calculated and compared to those of TG-43U1. RESULTS: The dose to point A considering the metal applicator was 3.2% lower than that of TG-43U1, but there was no difference in the dose to point A considering the resin applicator. The dose distribution considering the metal applicator was lower than that of TG-43U1 at all calculation points, but there was no difference in the dose distribution considering the resin applicator at almost all calculation points. CONCLUSION: In this study, the dose distribution considering the metal applicator was lower than that of TG-43U1 at all calculation points, but there was no difference in the dose distribution considering the resin applicator at almost all calculation points. Therefore, TG-43U1 can accurately calculate the dose distribution when changing from the metal applicator to the resin applicator.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Graduate School of Health Sciences, Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences.
- Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences.
- Department of Radiation Technology, Ibaraki Prefectural Central Hospital.
- Department of Radiology, Tsuchiura Kyodo General Hospital.
- Department of Radiation Oncology, Ibaraki Prefectural Central Hospital.
- Department of Radiation Oncology, Fukushima Rosai Hospital.
Zitieren
APA
Tomita, F., Fuse, H., Fujisaki, T., Yasue, K., Miyakawa, S., Ikoma, H., Yoshizawa, T., Oyama, K., Oyama, S., Okumura, T., & Tamaki, Y. (2023). Verification of Dose Distribution in Cervical Cancer Brachytherapy Using Metal and Plastic Applicators. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.2023-1375
Vancouver
Tomita F, Fuse H, Fujisaki T, Yasue K, Miyakawa S, Ikoma H, et al. Verification of Dose Distribution in Cervical Cancer Brachytherapy Using Metal and Plastic Applicators. Japanese Journal of Radiological Technology. 2023. doi:10.6009/jjrt.2023-1375
BibTeX
@article{Tomita2023,
author = {Tomita, Fumihiro and Fuse, Hiraku and Fujisaki, Tatsuya and Yasue, Kenji and Miyakawa, Sin and Ikoma, Hideaki and Yoshizawa, Tomoyuki and Oyama, Katsuhiko and Oyama, Satoshi and Okumura, Toshiyuki and Tamaki, Yoshio},
title = {Verification of Dose Distribution in Cervical Cancer Brachytherapy Using Metal and Plastic Applicators},
journal = {Japanese Journal of Radiological Technology},
year = {2023},
doi = {10.6009/jjrt.2023-1375}
}
EUVIMED