EUVIMEDEUVIMED entdecken
Crossref

Clinical Usefulness of Ultra-short TE MRA for Follow-up Imaging after Cerebral Aneurysm Clipping

Saki Takubo, Kohei Kawasaki, Tsutomu Nagatari, Masanobu Matsumoto, Takahiro Kageyama

Japanese Journal of Radiological Technology · 2020 · 76 (2) · 177-184

DOI: 10.6009/jjrt.2020_jsrt_76.2.177 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2020. Verfasst von Saki Takubo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Chiba Cerebral and Cardiovascular Center. Hauptthemen laut MEDLINE: Cerebral Angiography, Magnetic Resonance Angiography. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aims of this study were to elucidate signal pattern of cerebral aneurysm clip in brain magnetic resonance angiography (MRA) using non-contrast enhanced ultra-short echo time (UTE) sequence and to explore effective utilization of this novel technique for patients, who underwent cerebral aneurysm clipping. The clip was embedded in homemade phantom and scanned using UTE sequence. We investigated characteristic features of the artifacts derived from the clip. Besides, we compared the volume of signal loss between conventional time-of-flight (TOF) and UTE-MRA in 50 patients with the cerebral aneurysm clip. In phantom study, the clip was delineated as signal void area fully surrounded by high signal on original images. On reconstructed short-axial views for the clip, four-leaf clover pattern of artifact was observed when clip was arranged orthogonal to the static magnetic field. On the other hand, this artifact disappeared when the clip was arranged in parallel with the static magnetic field. The volume of signal loss in clinical cases was significantly reduced in UTE-MRA (P < 0.05): 1.30, 0.52-2.77 cm3 for TOF; 0.84, 0.28-1.74 cm3 for UTE (median, range). The scan time for UTE-MRA was 2 minutes and 52 seconds. To understand the characteristic feature of the artifacts from the clip could contribute to define vascular structure in image interpretation. Adding UTE-MRA to routine protocol is useful approach for follow-up imaging after cerebral aneurysm clipping with clinically acceptable prolongation of the scan time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cerebral AngiographyMagnetic Resonance AngiographyArtifactsFollow-Up StudiesHumansIntracranial AneurysmPhantoms, Imaging

Stichwörter der Autor:innen

aneurysmcerebral aneurysm clipmagnetic resonance angiography(MRA)resonance offsetultra-short echo time(UTE)

Autor:innen und Institutionen

  • Chiba Cerebral and Cardiovascular Center.

Zitieren

APA

Takubo, S., Kawasaki, K., Nagatari, T., Matsumoto, M., & Kageyama, T. (2020). Clinical Usefulness of Ultra-short TE MRA for Follow-up Imaging after Cerebral Aneurysm Clipping. Japanese Journal of Radiological Technology, 76(2), 177-184. https://doi.org/10.6009/jjrt.2020_jsrt_76.2.177

Vancouver

Takubo S, Kawasaki K, Nagatari T, Matsumoto M, Kageyama T. Clinical Usefulness of Ultra-short TE MRA for Follow-up Imaging after Cerebral Aneurysm Clipping. Japanese Journal of Radiological Technology. 2020;76(2):177-184. doi:10.6009/jjrt.2020_jsrt_76.2.177

BibTeX
@article{Takubo2020,
  author = {Takubo, Saki and Kawasaki, Kohei and Nagatari, Tsutomu and Matsumoto, Masanobu and Kageyama, Takahiro},
  title = {Clinical Usefulness of Ultra-short TE MRA for Follow-up Imaging after Cerebral Aneurysm Clipping},
  journal = {Japanese Journal of Radiological Technology},
  year = {2020},
  volume = {76},
  number = {2},
  pages = {177--184},
  doi = {10.6009/jjrt.2020_jsrt_76.2.177}
}
Kostenlos starten →