EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Analysis of the Effect of Temperature on the Accuracy of Moisture Content Measurement in Transformer Oil

Lince Markis, Paulus Susetyo Wardana, Indra Budi H

International Journal of Integrative Research · 01.07.2026 · 4 (6) · 393-408

DOI: 10.59890/ijir.v4i6.200 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Integrative Research, online erschienen am 01.07.2026. Verfasst von Lince Markis und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transformer oil plays a critical role in insulation and cooling systems in power transformers. One of the key parameters affecting transformer reliability is moisture content, as excessive water contamination can reduce dielectric strength and accelerate insulation degradation. However, moisture measurement accuracy is strongly influenced by oil temperature variations during testing. This study aims to analyze the effect of temperature on the accuracy of moisture content measurements in transformer oil. The research employed an experimental approach using transformer oil samples tested at different temperature levels ranging from 20°C to 80°C. Moisture measurements were conducted using a capacitive moisture sensor and compared with Karl Fischer Titration (KFT) as the reference method. The results indicate that increasing temperature significantly affects measurement stability and accuracy. At higher temperatures, moisture readings tend to increase due to enhanced molecular activity and water solubility in oil. Statistical analysis shows that temperature contributes substantially to measurement deviation, with the highest accuracy obtained within the temperature range of 40°C–50°C. The maximum relative error reached 9.88% at 80°C, while the minimum error of 1.66% was observed at 50°C. The overall performance measured yielded an MAE of 1.29 ppm and an RMSE of 1.63 ppm. The study concludes that temperature compensation mechanisms are necessary to improve the reliability of real-time transformer oil monitoring systems

Zitieren

APA

Markis, L., Wardana, P. S., & H, I. B. (2026). Analysis of the Effect of Temperature on the Accuracy of Moisture Content Measurement in Transformer Oil. International Journal of Integrative Research, 4(6), 393-408. https://doi.org/10.59890/ijir.v4i6.200

Vancouver

Markis L, Wardana PS, H IB. Analysis of the Effect of Temperature on the Accuracy of Moisture Content Measurement in Transformer Oil. International Journal of Integrative Research. 2026;4(6):393-408. doi:10.59890/ijir.v4i6.200

BibTeX
@article{Markis2026,
  author = {Markis, Lince and Wardana, Paulus Susetyo and H, Indra Budi},
  title = {Analysis of the Effect of Temperature on the Accuracy of Moisture Content Measurement in Transformer Oil},
  journal = {International Journal of Integrative Research},
  year = {2026},
  volume = {4},
  number = {6},
  pages = {393--408},
  doi = {10.59890/ijir.v4i6.200}
}
Kostenlos starten →