Electrical Energy Audit at the Syekh Yusuf Regional Hospital Gowa Regency

Nur Fadilah Iswan, Zulhajji Zulhajji, Haripuddin Haripuddin

Energy Insights · 21.04.2026 · 1 (2) · 59-72

DOI: 10.59562/ei.v1i2.11452 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energy Insights, online erschienen am 21.04.2026. Verfasst von Nur Fadilah Iswan und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aimed to evaluate electrical energy consumption and determine the level of energy efficiency in the laboratory, radiology, and blood transfusion unit buildings at Syekh Yusuf Regional General Hospital, Gowa Regency, using the Energy Consumption Intensity (IKE) indicator and to identify practical energy-saving opportunities to support sustainable hospital energy management.

Methods

A quantitative descriptive energy audit approach was applied using field observations, measurements, and documentation of electricity consumption data from January to October 2023. Monthly Energy Consumption Intensity (IKE) values were calculated in kWh/m²/month based on the total electricity usage and building floor area. Lighting performance was assessed using lux meter measurements according to national standards, and cooling system requirements were analyzed to evaluate the suitability of the installed air conditioning capacity. Energy-saving opportunities were classified as no-cost, low-cost, and high-cost measures based on implementation feasibility.

Results

The findings indicate that The average monthly IKE values of the laboratory, radiology, and blood transfusion unit buildings were 55.33, 50.32, and 176.02 kWh/m²/month, respectively, all categorized as inefficient according to national energy efficiency standards. Air-conditioning systems were identified as the dominant energy consumers in all buildings. The estimated potential energy savings were primarily derived from operational adjustments and cooling system optimization, indicating that system capacity mismatch significantly contributes to the excessive energy consumption. Novelty: This study presents an integrated energy audit framework that combines electrical load analysis, lighting performance evaluation, and cooling system capacity assessment to support prioritized energy-efficient actions in hospital facilities.

Zitieren

APA

Iswan, N. F., Zulhajji, Z., & Haripuddin, H. (2026). Electrical Energy Audit at the Syekh Yusuf Regional Hospital Gowa Regency. Energy Insights, 1(2), 59-72. https://doi.org/10.59562/ei.v1i2.11452

Vancouver

Iswan NF, Zulhajji Z, Haripuddin H. Electrical Energy Audit at the Syekh Yusuf Regional Hospital Gowa Regency. Energy Insights. 2026;1(2):59-72. doi:10.59562/ei.v1i2.11452

BibTeX
@article{Iswan2026,
  author = {Iswan, Nur Fadilah and Zulhajji, Zulhajji and Haripuddin, Haripuddin},
  title = {Electrical Energy Audit at the Syekh Yusuf Regional Hospital Gowa Regency},
  journal = {Energy Insights},
  year = {2026},
  volume = {1},
  number = {2},
  pages = {59--72},
  doi = {10.59562/ei.v1i2.11452}
}
Kostenlos starten →