Analysis of the Effect of Air Inlet Filter Replacement on Gas Turbine Performance at Unit 1A of Bekasi Power Combined Cycle Power Plant
Recent in Engineering Science and Technology · 31.10.2026 · 4 (4) · 245-254
DOI: 10.59511/riestech.v4i4.175 ↗Kurz gefasst
Fachartikel in der Zeitschrift Recent in Engineering Science and Technology, online erschienen am 31.10.2026. Verfasst von Gilang Fitra Ardiansyah und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The air inlet filter is a critical component in a gas turbine system because it ensures that clean air enters the compressor and combustion chamber. The accumulation of dust, moisture, and airborne contaminants can increase pressure drop across the filter, reducing airflow rate and adversely affecting compressor performance, combustion efficiency, and overall gas turbine operation. This study aims to analyze the effect of air inlet filter replacement on the performance of Gas Turbine GT1A at Bekasi Power Combined Cycle Power Plant (CCPP). A quantitative comparative approach was employed by comparing operational data before and after air inlet filter replacement. Secondary data were obtained from the Distributed Control System (DCS), including compressor inlet temperature, compressor outlettemperature, compressor inlet pressure, compressor outlet pressure, combustion chamber temperature, turbine exhaust temperature, fuel gas flow rate, and generator load. The performance analysis was conducted using Brayton cycle thermodynamic equations to evaluate compressor efficiency, combustion chamber efficiency, turbine efficiency, and thermal efficiency. Furthermore, a Fishbone Diagram (6M) analysis was utilized to identify the root causes leading to air inlet filter replacement. The results indicate that replacing the air inlet filter improves the quality and quantity of intake air supplied to the compressor, leading to enhanced combustion conditions andimproved gas turbine performance. The study highlights the importance of periodic air inlet filter maintenance in maintaining operational reliability, efficiency, and long-term performance of gas turbine systems
Zitieren
APA
Ardiansyah, G. F., & Yuliana, A. E. (2026). Analysis of the Effect of Air Inlet Filter Replacement on Gas Turbine Performance at Unit 1A of Bekasi Power Combined Cycle Power Plant. Recent in Engineering Science and Technology, 4(4), 245-254. https://doi.org/10.59511/riestech.v4i4.175
Vancouver
Ardiansyah GF, Yuliana AE. Analysis of the Effect of Air Inlet Filter Replacement on Gas Turbine Performance at Unit 1A of Bekasi Power Combined Cycle Power Plant. Recent in Engineering Science and Technology. 2026;4(4):245-254. doi:10.59511/riestech.v4i4.175
BibTeX
@article{Ardiansyah2026,
author = {Ardiansyah, Gilang Fitra and Yuliana, Arifia Eka},
title = {Analysis of the Effect of Air Inlet Filter Replacement on Gas Turbine Performance at Unit 1A of Bekasi Power Combined Cycle Power Plant},
journal = {Recent in Engineering Science and Technology},
year = {2026},
volume = {4},
number = {4},
pages = {245--254},
doi = {10.59511/riestech.v4i4.175}
}