Safety and efficacy of trans-afferent loop endoscopic ultrasound-guided pancreaticojejunostomy for post pancreaticoduodenectomy anastomotic stricture using the forward-viewing echoendoscope: a retrospective study from Japan
Clinical Endoscopy · 30.03.2025 · 58 (2) · 311-319
DOI: 10.5946/ce.2024.089 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Endoscopy, erschienen am 30.03.2025. Verfasst von Ahmed Sadek und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Faculty of Medicine, Helwan University, Cairo, Egypt. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Background/Aims: Endoscopic ultrasound (EUS)-guided pancreatic duct drainage is a well-established procedure for managing pancreaticojejunostomy anastomotic strictures (PJAS) post-Whipple surgery. In this study, we examined the effectiveness and safety of EUS-guided pancreaticojejunostomy (EUS-PJS).
Methods
This retrospective, single-arm study was performed at Aichi Cancer Center Hospital on 10 patients who underwent EUS-guided pancreaticojejunostomy through the afferent jejunal loop using a forward-viewing echoendoscope when endoscopic retrograde pancreatography failed. Our primary endpoint was technical success rate, defined as successful stent insertion. The secondary endpoints were early and late adverse events.
Results
A total of 10 patients underwent EUS-PJS between February 2019 and October 2023. The technical success rate was 100%. The median procedure time was 23.5 minutes. No remarkable early or late adverse events related to the procedure, except for fever, occurred in two patients. The median follow-up duration was 9.5 months, and the median number of stent exchanges was two. A stent-free state was achieved in three patients.
Conclusions
EUS-PJS for PJAS management after pancreaticoduodenectomy appears to be an effective and safe procedure with the potential advantages of fewer reinterventions and the creation of a permanent drainage fistula.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine, Faculty of Medicine, Helwan University, Cairo, Egypt.
- Department of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
- Department of Medicine and Therapeutics, University of Ghana Medical School, Korle Bu Teaching Hospital, Accra, Ghana.
Zitieren
APA
Sadek, A., Hara, K., Okuno, N., Haba, S., Kuwahara, T., Fukui, T., Urata, M., Kondo, T., Yamamoto, Y., & Tachi, K. (2025). Safety and efficacy of trans-afferent loop endoscopic ultrasound-guided pancreaticojejunostomy for post pancreaticoduodenectomy anastomotic stricture using the forward-viewing echoendoscope: a retrospective study from Japan. Clinical Endoscopy, 58(2), 311-319. https://doi.org/10.5946/ce.2024.089
Vancouver
Sadek A, Hara K, Okuno N, Haba S, Kuwahara T, Fukui T, et al. Safety and efficacy of trans-afferent loop endoscopic ultrasound-guided pancreaticojejunostomy for post pancreaticoduodenectomy anastomotic stricture using the forward-viewing echoendoscope: a retrospective study from Japan. Clinical Endoscopy. 2025;58(2):311-319. doi:10.5946/ce.2024.089
BibTeX
@article{Sadek2025,
author = {Sadek, Ahmed and Hara, Kazuo and Okuno, Nozomi and Haba, Shin and Kuwahara, Takamichi and Fukui, Toshitaka and Urata, Minako and Kondo, Takashi and Yamamoto, Yoshitaro and Tachi, Kenneth},
title = {Safety and efficacy of trans-afferent loop endoscopic ultrasound-guided pancreaticojejunostomy for post pancreaticoduodenectomy anastomotic stricture using the forward-viewing echoendoscope: a retrospective study from Japan},
journal = {Clinical Endoscopy},
year = {2025},
volume = {58},
number = {2},
pages = {311--319},
doi = {10.5946/ce.2024.089}
}
EUVIMED