Simulation of Positron Lifetime Spectra in Aluminium: Influence of Time Response Function and Detector Configuration

Duaa Hatif Mohammed, Mohanad Hussein Oleiwi

Applied Chemical Engineering · 30.06.2026

DOI: 10.59429/ace.v9i2.5895 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Chemical Engineering, online erschienen am 30.06.2026. Verfasst von Duaa Hatif Mohammed und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the influence of various factors on the quality and analysis of positron lifetime spectra. Theoretical simulations were performed to examine how these factors affect the quality and analysis of the positron annihilation spectrum. An aluminium (Al) sample was used to assess the spectra quality. The factors studied in this simulation were: the thickness of the material, the gap between the sample and detectors, and the angle between the two detectors. The thickness of the material was varied as 0.5,1, 1.5, 2, 2.5, 3, 3.5 and 4 mm, and the gap was varied as: 1, 2, 3,4,5,6,7 and 8 n air, and the angle was varied as:180o,190o,200o and 210o. The positron annihilation spectra were analyzed using the PEPEPOSFIT program to obtain the values of the lifetime components and the resolution function (FWHM). It was observed that as the thickness of the sample material and the gap between the sample-source sandwich and detectors increases, the spectra become distorted. Furthermore, with an increase in the angle between the two detectors, the spectra become highly distorted. The setup with two detectors in a collinear (180°) geometry yielded the optimal spectrum. The spectra deviated from this optimal shape as the angle increased. At an angle of 210°, the spectrum was completely distorted, where three peaks appeared. This is attributed to the effect of the non-collinearity function on the integrity of the positron lifetime spectrum.

Zitieren

APA

Mohammed, D. H., & Oleiwi, M. H. (2026). Simulation of Positron Lifetime Spectra in Aluminium: Influence of Time Response Function and Detector Configuration. Applied Chemical Engineering. https://doi.org/10.59429/ace.v9i2.5895

Vancouver

Mohammed DH, Oleiwi MH. Simulation of Positron Lifetime Spectra in Aluminium: Influence of Time Response Function and Detector Configuration. Applied Chemical Engineering. 2026. doi:10.59429/ace.v9i2.5895

BibTeX
@article{Mohammed2026,
  author = {Mohammed, Duaa Hatif and Oleiwi, Mohanad Hussein},
  title = {Simulation of Positron Lifetime Spectra in Aluminium: Influence of Time Response Function and Detector Configuration},
  journal = {Applied Chemical Engineering},
  year = {2026},
  doi = {10.59429/ace.v9i2.5895}
}
Kostenlos starten →