EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Study of the mechanical behavior under compression of a tetrachiral auxetic tubular structure

Ali Bejaoui, Ltaief Lammari, Fethi Abbassi, Ali Trabelsi, Mohamed-Ali Rezgui

Sound & Vibration · 14.08.2026

DOI: 10.59400/sv4310 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sound & Vibration, online erschienen am 14.08.2026. Verfasst von Ali Bejaoui und 4 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Additive manufacturing enables the fabrication of architected materials with geometries unattainable through conventional processes. Among these, auxetic metastructures, characterized by a negative Poisson's ratio, have attracted considerable interest owing to their unusual deformation mechanisms and superior energy absorption and dissipation. This study investigates the mechanical behavior of a tetrachiral tubular structure made of AA7075-T651 aluminum alloy under axial compression, focusing on the influence of boundary conditions at the part–machine interfaces. Finite element simulations accounted for frictional contact, geometric nonlinearity, and the rotational kinematics of tetrachiral cells. The results reveal that friction governs the onset and magnitude of the auxetic response. Under highly constrained contact (μ = 0.8), ligament rotation is suppressed, and the structure deforms conventionally, exhibiting a positive effective Poisson's ratio (ν ≈ +0.28), limited twisting (two turns), and a maximum compressive load of 3.877 kN. Reducing friction to μ = 0.2 with a fixed base promotes in-plane node rotation, activating the tetrachiral mechanism and yielding ν ≈ −0.25, four turns, and a higher load of 3.883 kN. The most pronounced auxetic response arises when both ends are free to slide under low friction, producing ν ≈ −0.32, five turns, and an 8.2% contraction of the outer diameter. Across the investigated configurations, the effective Poisson's ratio varies by 0.60. These findings demonstrate that the auxetic behavior of tetrachiral tubes is highly sensitive to frictional and kinematic constraints, which must be carefully controlled to ensure reproducible mechanical performance.

Zitieren

APA

Bejaoui, A., Lammari, L., Abbassi, F., Trabelsi, A., & Rezgui, M. (2026). Study of the mechanical behavior under compression of a tetrachiral auxetic tubular structure. Sound & Vibration. https://doi.org/10.59400/sv4310

Vancouver

Bejaoui A, Lammari L, Abbassi F, Trabelsi A, Rezgui M. Study of the mechanical behavior under compression of a tetrachiral auxetic tubular structure. Sound & Vibration. 2026. doi:10.59400/sv4310

BibTeX
@article{Bejaoui2026,
  author = {Bejaoui, Ali and Lammari, Ltaief and Abbassi, Fethi and Trabelsi, Ali and Rezgui, Mohamed-Ali},
  title = {Study of the mechanical behavior under compression of a tetrachiral auxetic tubular structure},
  journal = {Sound & Vibration},
  year = {2026},
  doi = {10.59400/sv4310}
}
Kostenlos starten →