Coupling vibration analysis for aerial inspection robot landing on transmission line under wind disturbance
Sound & Vibration · 15.04.2026
DOI: 10.59400/sv4198 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sound & Vibration, online erschienen am 15.04.2026. Verfasst von Xiaodong Zhang und 3 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
When the high-voltage transmission line inspection robot (HVTIR) lands amid wind disturbances, line vibrations significantly affect system stability. Therefore, this paper proposes a contact-force control strategy for HVTIR landing based on varying wind speed conditions: a nonlinear contact-force model is preferred for vibration reduction under low wind speeds, while a linear contact-force model enhances stability under medium and high wind speeds. Using a composite wind field model, the vibration bending beam model of the transmission line and the mass-stiffness-damping coupling model of the robot under wind disturbance were developed. An experimental verification system was established using wireless acceleration sensors. Results showed that under a typical low wind speed of 2 m/s, the exponential nonlinear contact-force strategy controlled vibration at 0.64 m/s2, which was 90.1% more effective than direct loading. At a typical medium-high wind speed of 6 m/s, the experimental peak value using the linear contact-force strategy was reduced by 5.7% compared to the ideal peak value; the experimental RMS was reduced by 0.36%, and the linear contact-force strategy significantly reduced coupling vibrations. These experimental results demonstrate the reliability and applicability of the proposed control strategy, providing theoretical and technical support for the stable and rapid landing of the inspection robot.
Zitieren
APA
Zhang, X., Shen, H., Alhassan, A. B., & Xu, H. (2026). Coupling vibration analysis for aerial inspection robot landing on transmission line under wind disturbance. Sound & Vibration. https://doi.org/10.59400/sv4198
Vancouver
Zhang X, Shen H, Alhassan AB, Xu H. Coupling vibration analysis for aerial inspection robot landing on transmission line under wind disturbance. Sound & Vibration. 2026. doi:10.59400/sv4198
BibTeX
@article{Zhang2026,
author = {Zhang, Xiaodong and Shen, Haiming and Alhassan, Ahmad Bala and Xu, Haibo},
title = {Coupling vibration analysis for aerial inspection robot landing on transmission line under wind disturbance},
journal = {Sound & Vibration},
year = {2026},
doi = {10.59400/sv4198}
}
EUVIMED