Study on influencing factors of ultrasonic testing for lead seal defects in high-voltage cables
Sound & Vibration · 24.07.2026
DOI: 10.59400/sv4154 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sound & Vibration, online erschienen am 24.07.2026. Verfasst von Peng He und 4 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Lead seals are critical sealing and protective components of high-voltage cable terminations, and their structural integrity directly determines the safe and stable operation of urban power transmission systems. Conventional non-destructive testing methods face inherent limitations such as low penetration depth and susceptibility to heat-shrinkable protective layers, making ultrasonic phased array technology a promising alternative for lead-seal defect detection. However, imaging quality is often severely degraded by practical factors encountered in complex field inspection environments. This study systematically investigates the effects of coupling condition, surface roughness, and surface curvature on ultrasonic imaging performance for lead-seal defects. Three groups of controlled comparative experiments were conducted using artificially fabricated lead-seal specimens with predefined internal defects, varying surface roughness levels, and different curvature radii. A dedicated ultrasonic phased array testing platform equipped with a 5 MHz, 16-element probe was established to quantitatively evaluate imaging quality through metrics including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and bottom-wave amplitude. The results show that the improved flexible film coupling device provides significantly better imaging quality than the conventional rigid wedge, with 28.5% higher SNR and 27.8% higher CNR. In addition, increased surface roughness enhances diffuse reflection and reduces echo coherence, while surface curvature introduces spatial phase deviations that weaken bottom-wave response and increase defect interpretation difficulty. These findings provide essential experimental evidence and practical guidance for optimizing field inspection protocols and improving the reliability of ultrasonic testing for high-voltage cable lead seals.
Zitieren
APA
He, P., Cheng, J., Zhang, F., Wang, L., & Qian, C. (2026). Study on influencing factors of ultrasonic testing for lead seal defects in high-voltage cables. Sound & Vibration. https://doi.org/10.59400/sv4154
Vancouver
He P, Cheng J, Zhang F, Wang L, Qian C. Study on influencing factors of ultrasonic testing for lead seal defects in high-voltage cables. Sound & Vibration. 2026. doi:10.59400/sv4154
BibTeX
@article{He2026,
author = {He, Peng and Cheng, Jian and Zhang, Fengyin and Wang, Lianbing and Qian, Cen},
title = {Study on influencing factors of ultrasonic testing for lead seal defects in high-voltage cables},
journal = {Sound & Vibration},
year = {2026},
doi = {10.59400/sv4154}
}
EUVIMED