EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Configuration and fault location method for network with limited traveling wave recorder based on hypothetical fault

Yongqi Liu, Jianbo Nie, Luyao Xie, Chao Zhu, Youbing Zhang

Sound & Vibration · 13.03.2026

DOI: 10.59400/sv3856 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sound & Vibration, online erschienen am 13.03.2026. Verfasst von Yongqi Liu und 4 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fault location is crucial for enhancing power supply reliability and shortening power outage duration. Traditional power frequency-based fault location methods are limited by the distributed generation integration and the complex grid topology of renewable energy systems, while traveling wave (TW) fault location technology has become a research hotspot due to its high accuracy and fast response. The mainstream TW methods (single-ended, double-ended) have inherent drawbacks. This paper proposes a hypothetical fault-based fault location method: Acquire data from each sensor, obtain the time information of wavefronts via the db6 wavelet transform, and then construct a time matrix accordingly. Randomly assume a fault point, calculate the TW arrival time difference matrix between the hypothetical fault (based on shortest-path propagation) and the actual fault, derive the time information difference degree by comparing the two matrices, and iteratively update the hypothetical fault point via an optimization algorithm until the matrices coincide. Meanwhile, based on the hypothetical fault method, the mathematical expressions for the line fault observability constraints are derived, the optimal configuration model of traveling wave recorders in the network is established, and the solution is completed. This method achieves accurate fault location, assists in judging whether the network is measurable, and further enables the design of a planning and configuration model to realize the optimal configuration of TWRs under the condition of full-network fault observability without analyzing and deconstructing the network structure. Simulations are conducted on the IEEE 30-bus and IEEE 57-bus systems, respectively, to verify the method’s effectiveness.

Zitieren

APA

Liu, Y., Nie, J., Xie, L., Zhu, C., & Zhang, Y. (2026). Configuration and fault location method for network with limited traveling wave recorder based on hypothetical fault. Sound & Vibration. https://doi.org/10.59400/sv3856

Vancouver

Liu Y, Nie J, Xie L, Zhu C, Zhang Y. Configuration and fault location method for network with limited traveling wave recorder based on hypothetical fault. Sound & Vibration. 2026. doi:10.59400/sv3856

BibTeX
@article{Liu2026,
  author = {Liu, Yongqi and Nie, Jianbo and Xie, Luyao and Zhu, Chao and Zhang, Youbing},
  title = {Configuration and fault location method for network with limited traveling wave recorder based on hypothetical fault},
  journal = {Sound & Vibration},
  year = {2026},
  doi = {10.59400/sv3856}
}