EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Correlation between fractional clearance and optical outcomes of LASIK myopia correction

Milorad Milivojević, Snežana Knežević, Bojan Radojičić, Rada Zečević, Ivan Marjanović

Medicinski glasnik Specijalne bolnice za bolesti štitaste žlezde i bolesti metabolizma · 2026 · 31 (101) · 35-45

DOI: 10.5937/mgiszm2601035m ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medicinski glasnik Specijalne bolnice za bolesti štitaste žlezde i bolesti metabolizma, 2026. Verfasst von Milorad Milivojević und 4 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Excimer laser pulses using the LASIK method ablate the corneal stroma, achieving its remodeling to the desired optical characteristics. Besides correcting ametropia, it is desirable to minimize the induction of higher-order optical aberrations (HOA), as they affect the occurrence of glare and halos in night vision conditions. Fractional clearance (FC) represents the ratio of the treated optical zone (OZ) to the pupil diameter in scotopic lighting conditions. This study aims to examine the relationship between the enlargement of the treated OZ diameter and the increase in FC index on postoperative HOA levels. A prospective study included 37 subjects (74 eyes) with myopia treated with the LASIK method. The eye with a higher residual stromal bed value was treated with an OZ diameter of 7.0 mm, and the other eye of the same patient with an OZ diameter of 6.5 mm. After 6 months, an objective evaluation of optical outcomes was performed using an Analyzer device. The mean FC value in the group of eyes treated with OZ 6.5 mm is 2.138 (SD 0.30), and in the group treated with OZ 7.0 mm is 2.325 (SD 0.37), statistically significant (t=3.64; p<0.001). A smaller induction of all measured HOA was found when a wider OZ of 7.0 mm was treated, with the statistically significant reduction observed in spherical aberration induction. The increase in FC index is proportional to the enlargement of the treated OZ diameter. With an increase in FC value, the level of all HOA decreases after the LASIK procedure, with the most significant reduction observed in spherical aberration induction. Enlargement of OZ to 7.0 mm, when corneal structural characteristics allow it, improves postoperative optical outcomes.

Zitieren

APA

Milivojević, M., Knežević, S., Radojičić, B., Zečević, R., & Marjanović, I. (2026). Correlation between fractional clearance and optical outcomes of LASIK myopia correction. Medicinski glasnik Specijalne bolnice za bolesti štitaste žlezde i bolesti metabolizma, 31(101), 35-45. https://doi.org/10.5937/mgiszm2601035m

Vancouver

Milivojević M, Knežević S, Radojičić B, Zečević R, Marjanović I. Correlation between fractional clearance and optical outcomes of LASIK myopia correction. Medicinski glasnik Specijalne bolnice za bolesti štitaste žlezde i bolesti metabolizma. 2026;31(101):35-45. doi:10.5937/mgiszm2601035m

BibTeX
@article{Milivojevi2026,
  author = {Milivojević, Milorad and Knežević, Snežana and Radojičić, Bojan and Zečević, Rada and Marjanović, Ivan},
  title = {Correlation between fractional clearance and optical outcomes of LASIK myopia correction},
  journal = {Medicinski glasnik Specijalne bolnice za bolesti štitaste žlezde i bolesti metabolizma},
  year = {2026},
  volume = {31},
  number = {101},
  pages = {35--45},
  doi = {10.5937/mgiszm2601035m}
}
Kostenlos starten →