Abstract (Originalsprache)

Background/Aim: This study aimed to evaluate the precision of the Raypex 6 apex locator in locating the apical constriction (AC) and major foramen (MF) during a root canal treatment compared with a microscopic evaluation. Another aim of the present study was to evaluate the accuracy of the Raypex 6 in the presence of different irrigating solutions (NaOCl, saline, EDTA, etidronic acid-HEBP). Material and Methods: One hundred and nine patients were included in this study and were randomly assigned into four groups according to the irrigation solution used; NaOCl, EDTA, HEBF and saline. Electronic MF (EMF) and AC (EAC) were measured by using Raypex 6. The teeth were extracted. The apical 3 mm of each canal was trimmed to expose the file tip. The samples were observed under a stereomicroscope, and the actual length of MF (ALMF) and AC (ALAC) were measured. The data were analyzed by using x2 test, and significance was set at P< 0.05.

Results

The Raypex 6 was accurate 71.4% of the time to ±0.5mm and 93.3% of the time to ±1mm in determining the ALAC. While similar ALAC-EAC differences were observed in EDTA, NaOCl, and saline groups (p= 0.230), the highest differences were seen in the HEBP group (p= 1.000). The precision of Raypex 6 in determining the working length measurement depends on the type of irrigation. All solutions allowed reliable detection of AC. However, HEBF significantly increased the risk of overpreparation.

Conclusions

Raypex 6 can be recommended for clinical use and its accuracy is not affected by the type of irrigant when locating MF.

Zitieren

APA

Peker, B., Hepsenoglu, Y., Ersahan, S., & Eyuboglu, T. (2022). Accuracy of working length measurement by Raypex 6: Electronic apex locator versus actual measurements under stereomicroscope. Balkan Journal of Dental Medicine, 26(3), 15-21. https://doi.org/10.5937/bjdm2201015p

Vancouver

Peker B, Hepsenoglu Y, Ersahan S, Eyuboglu T. Accuracy of working length measurement by Raypex 6: Electronic apex locator versus actual measurements under stereomicroscope. Balkan Journal of Dental Medicine. 2022;26(3):15-21. doi:10.5937/bjdm2201015p

BibTeX
@article{Peker2022,
  author = {Peker, Begum and Hepsenoglu, Yelda and Ersahan, Seyda and Eyuboglu, Tan},
  title = {Accuracy of working length measurement by Raypex 6: Electronic apex locator versus actual measurements under stereomicroscope},
  journal = {Balkan Journal of Dental Medicine},
  year = {2022},
  volume = {26},
  number = {3},
  pages = {15--21},
  doi = {10.5937/bjdm2201015p}
}
Kostenlos starten →